{"product_id":"rotary-fiber-photometry-system","title":"Rotary Fiber Photometry System","description":"\u003cp\u003e \u003c\/p\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli\u003e\u003ca href=\"#tab1\" class=\"active\"\u003eDESCRIPTION\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"#tab2\"\u003eGCaMP\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"#tab3\"\u003eGCaMP + Red Fluo\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"#tab4\"\u003eFRET (CFP\/YFP)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"#tab5\"\u003eSUPPORT\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli id=\"tab1\" class=\"active\"\u003e\n\u003cp\u003eRecording fluorescence related to neuronal activity within the brains of freely moving tethered laboratory animals is often hindered by transmission losses and signal fluctuations resulting from rotary joint turns. To mitigate these challenges, we strategically position the Fluorescence Mini Cube with integrated LEDs and detectors at the bottom of a rotating part of a 24-channel Assisted Electrical Rotary Joint. This placement allows us to enhance overall optical transmission and effectively eliminate rotation-related artifacts.\u003c\/p\u003e\n\u003cp\u003eMoreover, the rotary joint features a central hole or lumen, facilitating the passage of an optical fiber for optogenetic stimulation and\/or a tube for liquid delivery.\u003c\/p\u003e\n\u003cp\u003eThe Rotary Fiber Photometry System is highly adaptable. It can be tailored to support alternative light sources, such as laser diodes, and accommodate various fluorophores, ensuring versatility for different experimental setups.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003ciframe src=\"https:\/\/doriclenses.com\/downloads\/video\/Photometry_system_RFMC.mp4\" height=\"405\" width=\"720\"\u003e\n\u003c\/iframe\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli id=\"tab2\"\u003e\n\u003cp\u003eThe Rotary Fluorescence Mini Cube for GCaMP has 4 ports, two integrated LEDs, and one integrated Fluorescence Detector. It records calcium-independent GCaMP fluorescence, excited by 405, 415, 425, or 440 nm light (isosbestic point), and its calcium-dependent fluorescence, excited by 470 nm light, with a single photodetector. The calcium-dependent GCaMP's fluorescence emission is separated from calcium-independent emission by lock-in amplifier detection or by interleaved excitations.\u003c\/p\u003e\n\u003cstrong\u003e\u003cbr\u003eThe Rotary Fiber Photometry System for GCaMP includes:\u003c\/strong\u003e \u003cbr\u003e\n\u003cul style=\"list-style: disc;\"\u003e\n\u003cli\u003e\n\u003ca href=\"\/fr\/products\/fiber-photometry-console\" target=\"_blank\"\u003eFiber Photometry Console\u003c\/a\u003e, the core of the system\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/fr\/products\/led-drivers?productoption%5BNumber%20of%20Channels%5D=2\" target=\"_blank\"\u003e2-channels LED Driver\u003c\/a\u003e to control LED power\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/fr\/products\/assisted-electrical-rotary-joints-for-fluorescence-mini-cubes\" target=\"_blank\"\u003e Assisted Rotary-Joint\u003c\/a\u003e with Holder\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/fr\/products\/rfmc4-gcamp?\" target=\"_blank\"\u003e Rotary Fluorescence Mini Cube - GCaMP\u003c\/a\u003e\u003ca href=\"https:\/\/neuro.doriclenses.com\/collections\/rotary-fluorescence-mini-cubes\/products\/rfmc4-gcamp?\" target=\"_blank\"\u003e \u003c\/a\u003e with built-in LEDs and DETECTOR\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/fr\/products\/doric-neuroscience-studio\" target=\"_blank\"\u003eDoric Neuroscience Studio\u003c\/a\u003e software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cstrong\u003eOptional items: \u003c\/strong\u003e\u003cbr\u003e\n\u003cul style=\"list-style: disc;\"\u003e\n\u003cli\u003e\n\u003ca href=\"\/fr\/products\/fiber-photometry-cannula-holder\" target=\"_blank\"\u003eFiber Photometry Cannula Holder\u003c\/a\u003e to record during surgery\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/fr\/products\/fiber-photometry-rack-pr5\" target=\"_blank\"\u003eFiber Photometry Rack\u003c\/a\u003e with parts pre-assembled\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/neuro.doriclenses.com\/collections\/behavior-camera\/products\/behavior-camera\"\u003eBehavior Camera\u003c\/a\u003e or \u003ca href=\"https:\/\/neuro.doriclenses.com\/collections\/behavior-camera\/products\/camloop\"\u003eCamLoop\u003c\/a\u003e to record animal behavior\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/fr\/products\/calibrated-power-meter-pronto-si\" target=\"_blank\"\u003e Optical Power meter\u003c\/a\u003e to monitor and calibrate excitation power\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/neuro.doriclenses.com\/products\/computeur?_pos=1\u0026amp;_sid=200a6c079\u0026amp;_ss=r\u0026amp;productoption%5BWorkstation%3A%5D=High%20performance\"\u003eWorkstation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/neuro.doriclenses.com\/products\/danse\"\u003edanse™\u003c\/a\u003e analyzing software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cstrong\u003eAccessories:\u003c\/strong\u003e\u003cbr\u003e\n\u003cul style=\"list-style: disc;\"\u003e\n\u003cli\u003e\n\u003ca href=\"\/fr\/products\/laf-patch-cords\" target=\"_blank\"\u003e Low-autofluorescence optical patch cords\u003c\/a\u003e to bring light to the animal\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/fr\/products\/mono-fiber-optic-cannulas\" target=\"_blank\"\u003eFiber-optic Cannulas\u003c\/a\u003e for chronic implant\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/fr\/products\/mating-sleeves\" target=\"_blank\"\u003eMating sleeves\u003c\/a\u003e for ferrule to ferrule interconnect\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli id=\"tab3\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan class=\"fontstyle0\" data-mce-fragment=\"1\"\u003eThe Rotary Fluorescence Mini Cube with 6 ports-FRET GCaMP Isosbestic \u0026amp; Functional Excitations, \u0026amp; Red Fluorophore Fluorescence contains three integrated LED and two integrated Fluorescence Detectors. This cube can be used to detect the fluorescence from two calcium indicators and the GCaMP isosbestic point. The separation of functional and isosbestic fluorescnece signals of GCaMP is possible if the light source are modulated using lock-in demodulation or sequential detection.\u003c\/span\u003e\u003c\/p\u003e\n\u003cstrong\u003eThe Rotary Fiber Photometry System for GCaMP and red fluorophore includes:\u003c\/strong\u003e \u003cbr\u003e\n\u003cul style=\"list-style: disc;\" data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003ca href=\"\/fr\/products\/fiber-photometry-console\" data-mce-fragment=\"1\" target=\"_blank\"\u003eFiber Photometry Console\u003c\/a\u003e, the core of the system\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003ca href=\"\/fr\/products\/led-drivers?productoption%5BNumber%20of%20Channels%5D=2\" data-mce-fragment=\"1\" target=\"_blank\"\u003e2-channels LED Driver\u003c\/a\u003e to control LED power\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003ca href=\"\/fr\/products\/assisted-electrical-rotary-joints-for-fluorescence-mini-cubes\" target=\"_blank\"\u003e Assisted Rotary-Joint\u003c\/a\u003e with Holder\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003ca href=\"\/fr\/collections\/rotary-fluorescence-mini-cubes\/products\/rfmc6\" target=\"_blank\"\u003e Rotary Fluorescence Mini Cube - GCaMP and red fluorophore\u003c\/a\u003e with built-in LEDs and DETECTORs\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003ca href=\"\/fr\/products\/doric-neuroscience-studio\" data-mce-fragment=\"1\" target=\"_blank\"\u003eDoric Neuroscience Studio\u003c\/a\u003e software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003eOptional items:\u003c\/strong\u003e \u003cbr data-mce-fragment=\"1\"\u003e\n\u003cul style=\"list-style: disc;\" data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003ca href=\"\/fr\/products\/fiber-photometry-cannula-holder\" data-mce-fragment=\"1\" target=\"_blank\"\u003eFiber Photometry Cannula Holder\u003c\/a\u003e to record during surgery\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003ca href=\"\/fr\/products\/fiber-photometry-rack-pr5\" data-mce-fragment=\"1\" target=\"_blank\"\u003eFiber Photometry Rack\u003c\/a\u003e with parts pre-assembled\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/neuro.doriclenses.com\/collections\/behavior-camera\/products\/behavior-camera\"\u003eBehavior Camera\u003c\/a\u003e or \u003ca href=\"https:\/\/neuro.doriclenses.com\/collections\/behavior-camera\/products\/camloop\"\u003eCamLoop\u003c\/a\u003e to record animal behavior\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003ca title=\"POWER METER\" href=\"https:\/\/neuro.doriclenses.com\/collections\/fiber-photometry-accessories\/products\/calibrated-power-meter-pronto-si\" target=\"_blank\"\u003e Optical Power meter\u003c\/a\u003e to monitor and calibrate excitation power\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/neuro.doriclenses.com\/products\/computeur?_pos=1\u0026amp;_sid=200a6c079\u0026amp;_ss=r\u0026amp;productoption%5BWorkstation%3A%5D=High%20performance\"\u003eWorkstation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/neuro.doriclenses.com\/products\/danse\"\u003edanse™\u003c\/a\u003e analyzing software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cstrong\u003eAccessories:\u003c\/strong\u003e\u003cbr\u003e\n\u003cul style=\"list-style: disc;\"\u003e\n\u003cli\u003e\n\u003ca href=\"\/fr\/products\/laf-patch-cords\" target=\"_blank\"\u003e Low-autofluorescence optical patch cords\u003c\/a\u003e to bring light to the animal\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/fr\/products\/mono-fiber-optic-cannulas\" target=\"_blank\"\u003eFiber-optic Cannulas\u003c\/a\u003e for chronic implant\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/fr\/products\/mating-sleeves\" target=\"_blank\"\u003eMating sleeves\u003c\/a\u003e for ferrule to ferrule interconnect\u003c\/li\u003e\n\u003cli\u003eRed Laser light source or Ce:YAG\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli id=\"tab4\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan class=\"fontstyle0\" data-mce-fragment=\"1\"\u003eThe Rotary Fluorescence Mini Cube with 4 ports FRET CFP\/YFP contains an excitation LED at 420 nm with two integrated Fluorescence Detectors for ratiometric measurement of the 520 and 550 nm emissions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cstrong\u003eThe Rotary Fiber Photometry System for FRET CFP\/YFP includes:\u003c\/strong\u003e \u003cbr\u003e\n\u003cul style=\"list-style: disc;\" data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003ca href=\"\/fr\/products\/fiber-photometry-console\" data-mce-fragment=\"1\" target=\"_blank\"\u003eFiber Photometry Console\u003c\/a\u003e, the core of the system\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003ca href=\"\/fr\/products\/led-drivers?productoption%5BNumber%20of%20Channels%5D=2\" data-mce-fragment=\"1\" target=\"_blank\"\u003e2-channels LED Driver\u003c\/a\u003e to control LED power\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003ca href=\"\/fr\/products\/assisted-electrical-rotary-joints-for-fluorescence-mini-cubes\" target=\"_blank\"\u003e Assisted Rotary-Joint\u003c\/a\u003e with Holder\u003cbr data-mce-fragment=\"1\"\u003e\n\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003ca href=\"\/fr\/collections\/rotary-fluorescence-mini-cubes\/products\/rfmc4-fret\" target=\"_blank\"\u003e Rotary Fluorescence Mini Cube - FRET\u003c\/a\u003e with built-in LEDs and DETECTOR\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003ca href=\"\/fr\/products\/doric-neuroscience-studio\" data-mce-fragment=\"1\" target=\"_blank\"\u003eDoric Neuroscience Studio\u003c\/a\u003e software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cstrong\u003eOptional items: \u003c\/strong\u003e\u003cbr\u003e\n\u003cul style=\"list-style: disc;\" data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003ca href=\"\/fr\/products\/fiber-photometry-cannula-holder\" data-mce-fragment=\"1\" target=\"_blank\"\u003eFiber Photometry Cannula Holder\u003c\/a\u003e to record during surgery\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003ca href=\"\/fr\/products\/fiber-photometry-rack-pr5\" data-mce-fragment=\"1\" target=\"_blank\"\u003eFiber Photometry Rack\u003c\/a\u003e with parts pre-assembled\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003ca title=\"Optical Power Meter\" href=\"https:\/\/neuro.doriclenses.com\/collections\/fiber-photometry-accessories\/products\/calibrated-power-meter-pronto-si\" target=\"_blank\"\u003eOptical Power meter\u003c\/a\u003e to monitor and calibrate excitation power\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/neuro.doriclenses.com\/collections\/behavior-camera\/products\/behavior-camera\"\u003eBehavior Camera\u003c\/a\u003e or \u003ca href=\"https:\/\/neuro.doriclenses.com\/collections\/behavior-camera\/products\/camloop\"\u003eCamLoop\u003c\/a\u003e to record animal behavior\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/neuro.doriclenses.com\/products\/computeur?_pos=1\u0026amp;_sid=200a6c079\u0026amp;_ss=r\u0026amp;productoption%5BWorkstation%3A%5D=High%20performance\"\u003eWorkstation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/neuro.doriclenses.com\/products\/danse\"\u003edanse™\u003c\/a\u003e analyzing software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cstrong\u003eAccessories:\u003c\/strong\u003e\u003cbr\u003e\n\u003cul style=\"list-style: disc;\"\u003e\n\u003cli\u003e\n\u003ca href=\"\/fr\/products\/laf-patch-cords\" target=\"_blank\"\u003e Low-autofluorescence optical patch cords\u003c\/a\u003e to bring light to the animal\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/fr\/products\/mono-fiber-optic-cannulas\" target=\"_blank\"\u003eFiber-optic Cannulas\u003c\/a\u003e for chronic implant\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/fr\/products\/mating-sleeves\" target=\"_blank\"\u003eMating sleeves\u003c\/a\u003e for ferrule to ferrule interconnect\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli id=\"tab5\"\u003e\n\u003ctable style=\"width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #eeeeee;\"\u003e\n\u003ctd style=\"border: 0px; width: 100%; display: grid; grid-template-columns: 80% 20%; padding: 5px 5px 5px 5px 0px 5px;\"\u003e\u003cspan style=\"padding: 0px 0px 0px 10px; margin: 0px 0px 1px 0px; white-space: nowrap;\"\u003e\u003cstrong\u003eDrawing\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 0px; width: 100%; display: grid; grid-template-columns: 80% 20%; padding: 5px 5px 5px 5px;\"\u003e\n\u003cp style=\"margin: 0px 0px 0px 40px; border: none; padding: 0px;\"\u003eRFMC cube\u003c\/p\u003e\n\u003ca title=\"RFMC cube Drawing\" href=\"https:\/\/doriclenses.com\/downloads\/drawings\/Drawing_RFMC-cube.pdf\" rel=\"noopener\" target=\"_blank\"\u003e\u003ci data-darkreader-inline-color=\"\" style=\"margin: 0 0 0 95px; color: firebrick;\" class=\"fas fa-file-pdf fa-2x\"\u003e\u003c\/i\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #eeeeee;\"\u003e\n\u003ctd style=\"border: 0px; width: 100%; display: grid; grid-template-columns: 80% 10% 10%; padding: 5px 5px 5px 5px 0px 5px;\"\u003e\n\u003cspan style=\"padding: 0px 0px 0px 10px; margin: 0px 0px 1px 0px; white-space: nowrap;\"\u003e\u003cstrong\u003eGetting Started\u003c\/strong\u003e\u003c\/span\u003e\u003cspan style=\"padding: 0px 0px 0px 10px; margin: 0px 0px 1px 0px; white-space: nowrap; text-align: center;\"\u003e\u003cstrong\u003eFr\u003c\/strong\u003e\u003c\/span\u003e\u003cspan style=\"padding: 0px 0px 0px 10px; margin: 0px 0px 1px 0px; white-space: nowrap; text-align: center;\"\u003e\u003cstrong\u003eEn\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 0px; width: 100%; display: grid; grid-template-columns: 80% 10% 10%; padding: 5px 5px 5px 5px 0px 5px;\"\u003e\n\u003cp style=\"margin: 0 0 0 40px; border: none; padding: 0px;\"\u003eRotary Basic Fiber Photmetry System\u003c\/p\u003e\n\u003ca title=\"Manuel Utilisateur du Système de mini-cubes à fluorescence rotatative Configuration à deux cubes\" href=\"https:\/\/doriclenses.com\/downloads\/documents\/GettingStarted_RFMC_FR_V1.0.2.pdf\" target=\"_blank\"\u003e\u003ci style=\"margin: 0 0 0 47px; color: #3687ff;\" class=\"fas fa-file-pdf fa-2x\"\u003e\u003c\/i\u003e\u003c\/a\u003e \u003ca title=\"Rotary Fluorescence Mini Cube System Two cubes configuration user manuel\" href=\"https:\/\/doriclenses.com\/downloads\/documents\/GettingStarted_RFMC_V1.0.2.pdf\" target=\"_blank\"\u003e\u003ci style=\"margin: 0 0 0 47px; color: firebrick;\" class=\"fas fa-file-pdf fa-2x\"\u003e\u003c\/i\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Doric Lenses Inc.","offers":[{"title":"Default Title","offer_id":33584759472260,"sku":"","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0306\/2680\/7940\/products\/RFMC_1FMC-GCaMP_UPDATE.png?v=1669064817","url":"https:\/\/archive.neuro.doriclenses.com\/fr\/products\/rotary-fiber-photometry-system","provider":"Doric Lenses - Archive","version":"1.0","type":"link"}