{"product_id":"2-color-fluorescence-microscopy-system","title":"2-color Fluorescence Microscopy System","description":"\u003cul class=\"tabs\"\u003e\n\u003cli\u003e\u003ca class=\"active\" href=\"#tab1\"\u003eDESCRIPTION\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"#tab2\"\u003eSPECIFICATIONS\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"#tab3\"\u003eSUPPORT\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\" id=\"tab1\"\u003e\n\u003cmeta charset=\"UTF-8\"\u003e\n\u003cp\u003e2-color microscopy systems are designed to record simultaneously the fluorescence of red (RFP-like) and green (GFP-like) fluorescent markers. In opposition to single color microscope bodies, 2-color microscope bodies are optimized for a specific imaging depth, Available options are: \u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e2-color Model S: 0 - 150 µm deep below the brain surface (with a glass window)\u003c\/li\u003e\n\u003cli\u003e2-color Model L-D: 0 - 3.4 mm deep below the skull surface\u003c\/li\u003e\n\u003cli\u003e2-color Model L-V: 3.0 - 5.9 mm deep below the skull surface\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003eThe systems include: \u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/2-color-fluorescence-microscope-bodies?\" target=\"_blank\"\u003e2-color Microscope Body\u003c\/a\u003e, Model S, L-D or L-V depending on the targeted depth\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/2-color-fluorescence-microscope-driver?\" target=\"_blank\"\u003e2-color Fluorescence Microscope Driver\u003c\/a\u003e, to control the microscope\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/ceyag-led-light-source\" target=\"_blank\"\u003eCe:YAG + Blue LED Light Source\u003c\/a\u003e, for Green and Red Fluorescent markers excitation\u003c\/li\u003e\n\u003cli\u003eOptical fiber patch cords, to connect the light source to the microscope\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/doric-neuroscience-studio\" target=\"_blank\"\u003eDoric Neuroscience Studio\u003c\/a\u003e Software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003eAdd optional items:\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/neuro.doriclenses.com\/collections\/fiber-optic-electrical-rotary-joints\/products\/assisted-1x1-pigtailed-fiber-optic-electric-rotary-joints-24-contacts?\"\u003eAssisted 1x1 Pigtailed Fiber-optic \u0026amp; Electric Rotary Joint - HDMI+4, 24 contacts\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/2-color-dummy-microscope?\" target=\"_blank\"\u003e2-color Snap-in Microscope Dummy, Model S or L\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/fluorescence-microscope-holder-2?\" target=\"_blank\"\u003e2-color Fluorescence Microscope Holder\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/clamp-for-fluorescence-microscope-holder\" target=\"_blank\"\u003eClamp for Fluorescence Microscope Holder\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/neuro.doriclenses.com\/collections\/behavior-camera\/products\/behavior-camera\"\u003eBehavior Camera\u003c\/a\u003e to record animal behavior\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/neuro.doriclenses.com\/products\/computeur?_pos=1\u0026amp;_sid=200a6c079\u0026amp;_ss=r\u0026amp;productoption%5BWorkstation%3A%5D=High%20performance\"\u003eWorkstation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/neuro.doriclenses.com\/products\/danse\"\u003edanse™\u003c\/a\u003e analyzing software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003eComplete your system with:\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/snap-in-imaging-cannula-model-s\" target=\"_blank\"\u003eSnap-in Imaging Cannula, Model S\u003c\/a\u003e, or \u003ca href=\"\/products\/snap-in-imaging-cannula-model-l\" target=\"_blank\"\u003eSnap-in Imaging Cannula, Model L\u003c\/a\u003e, depending on the targeted depth\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/protrusion-adjustment-ring-set\" target=\"_blank\"\u003eProtrusion Adjustment Ring Set Model S or L\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli id=\"tab2\"\u003e\n\u003ctable class=\"table-data-sheet\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e   Field of view \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cmeta charset=\"UTF-8\"\u003e \u003cspan\u003e- Model L 320 µm x 320 µm\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e- Model S 730 µm x 730 µm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e   Objective lens numerical aperture\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e 0.4\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e   Frame rate\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e 45 FPS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e   Weigth\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e 3.7 g \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e   Computer specifications\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e - Intel Core-i7\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e - 16GB RAM\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e - Gigabit Ethernet, Jumbo frame compatible\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e - Dedicated graphic card \u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003e\u003cstrong\u003eSpectral bandwiths\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e   Green fluorescence sensor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e- Excitation 465 \/ 20 nm\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e- Emission 520 \/ 35 nm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e   Red fluorescence sensor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e- Excitation 563 \/ 9 nm\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e- Emission 615 \/ 45 nm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/li\u003e\n\u003cli id=\"tab3\"\u003e\n\u003ctable style=\"width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr data-darkreader-inline-bgcolor=\"\" style=\"background-color: #eeeeee;\"\u003e\n\u003ctd data-darkreader-inline-border-left=\"\" data-darkreader-inline-border-bottom=\"\" data-darkreader-inline-border-right=\"\" data-darkreader-inline-border-top=\"\" style=\"border: 0px; width: 100%; display: grid; grid-template-columns: 80% 20%; padding: 5px 5px 5px 5px 0px 5px;\"\u003e\u003cspan style=\"padding: 0px 0px 0px 10px; margin: 0px 0px 1px 0px; white-space: nowrap;\"\u003e\u003cstrong\u003eUser Manual\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-darkreader-inline-border-left=\"\" data-darkreader-inline-border-bottom=\"\" data-darkreader-inline-border-right=\"\" data-darkreader-inline-border-top=\"\" style=\"border: 0px; width: 100%; display: grid; grid-template-columns: 80% 10% 10%; padding: 5px 5px 5px 5px 0px 5px;\"\u003e\n\u003cp data-darkreader-inline-border-left=\"\" data-darkreader-inline-border-bottom=\"\" data-darkreader-inline-border-right=\"\" data-darkreader-inline-border-top=\"\" style=\"margin: 0 0 0 40px; border: none; padding: 0px;\"\u003e2-color Fluorescence Microscope User manuel\u003c\/p\u003e\n\u003ca href=\"https:\/\/doriclenses.com\/downloads\/UserManual\/UserManual_Microscope_2Colors_FR_V1.2.1.pdf\" title=\"Manuel utilisateur pour le Microscope à fluorescence bicolor\" target=\"_blank\"\u003e\u003ci data-darkreader-inline-color=\"\" class=\"fas fa-file-pdf fa-2x\" style=\"margin: 0 0 0 47px; color: #3687ff;\"\u003e\u003c\/i\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/doriclenses.com\/downloads\/UserManual\/UserManual_Microscope_2Colors_V1.2.1.pdf\" title=\"2-color Fluorescence Microscope EN User Manual\" target=\"_blank\"\u003e\u003ci data-darkreader-inline-color=\"\" class=\"fas fa-file-pdf fa-2x\" style=\"margin: 0 0 0 47px; color: firebrick;\"\u003e\u003c\/i\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-darkreader-inline-bgcolor=\"\" style=\"background-color: #eeeeee;\"\u003e\n\u003ctd data-darkreader-inline-border-left=\"\" data-darkreader-inline-border-bottom=\"\" data-darkreader-inline-border-right=\"\" data-darkreader-inline-border-top=\"\" style=\"border: 0px; width: 100%; display: grid; grid-template-columns: 80% 20%; padding: 5px 5px 5px 5px 0px 5px;\"\u003e\u003cspan style=\"padding: 0px 0px 0px 10px; margin: 0px 0px 1px 0px; white-space: nowrap;\"\u003e\u003cstrong\u003eApplication Notes\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-darkreader-inline-border-left=\"\" data-darkreader-inline-border-bottom=\"\" data-darkreader-inline-border-right=\"\" data-darkreader-inline-border-top=\"\" style=\"border: 0px; width: 100%; display: grid; grid-template-columns: 80% 10% 10%; padding: 5px 5px 5px 5px 0px 5px;\"\u003e\n\u003cp data-darkreader-inline-border-left=\"\" data-darkreader-inline-border-bottom=\"\" data-darkreader-inline-border-right=\"\" data-darkreader-inline-border-top=\"\" style=\"margin: 0 0 0 40px; border: none; padding: 0px;\"\u003eImaging Cannula Implantation \u0026amp; Microscope Installation for 2CFM Application Note\u003c\/p\u003e\n\u003ca href=\"http:\/\/www.doriclenses.com\/downloads\/ApplicationNotes\/ApplicationNote_2CFM_FR_V1.2.0.pdf\" title=\"Note d’Application pour l'Implantation de la canule d'imagerie et installation du microscope pour 2CFM\" target=\"_blank\"\u003e\u003ci data-darkreader-inline-color=\"\" class=\"fas fa-file-pdf fa-2x\" style=\"margin: 0 0 0 47px; color: #3687ff;\"\u003e\u003c\/i\u003e\u003c\/a\u003e \u003ca href=\"http:\/\/www.doriclenses.com\/downloads\/ApplicationNotes\/ApplicationNote_2CFM_V1.2.0.pdf\" title=\"Imaging Cannula Implantation and Microscope Installation for 2CFM Application Note\" target=\"_blank\"\u003e\u003ci data-darkreader-inline-color=\"\" class=\"fas fa-file-pdf fa-2x\" style=\"margin: 0 0 0 47px; color: firebrick;\"\u003e\u003c\/i\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-darkreader-inline-border-left=\"\" data-darkreader-inline-border-bottom=\"\" data-darkreader-inline-border-right=\"\" data-darkreader-inline-border-top=\"\" style=\"border: 0px; width: 100%; display: grid; grid-template-columns: 80% 10% 10%; padding: 5px 5px 5px 5px 0px 5px;\"\u003e\n\u003cp data-darkreader-inline-border-left=\"\" data-darkreader-inline-border-bottom=\"\" data-darkreader-inline-border-right=\"\" data-darkreader-inline-border-top=\"\" style=\"margin: 0 0 0 40px; border: none; padding: 0px;\"\u003eBehavior Camera: Synchronization and Recording\u003c\/p\u003e\n\u003ca href=\"http:\/\/www.doriclenses.com\/downloads\/ApplicationNotes\/ApplicationNote_Behavior_Camera_Synchronization_FR_V1.0.0.pdf\" title=\"Note d'application pour La synchronisation et l'enregistrement des cameras comportementales\" target=\"_blank\"\u003e\u003ci data-darkreader-inline-color=\"\" class=\"fas fa-file-pdf fa-2x\" style=\"margin: 0 0 0 47px; color: #3687ff;\"\u003e\u003c\/i\u003e\u003c\/a\u003e \u003ca href=\"http:\/\/www.doriclenses.com\/downloads\/ApplicationNotes\/ApplicationNote_Behavior_Camera_Synchronization_V1.0.0.pdf\" title=\"Behavior Camera: Synchronization and Recording Application Note\" target=\"_blank\"\u003e\u003ci data-darkreader-inline-color=\"\" class=\"fas fa-file-pdf fa-2x\" style=\"margin: 0 0 0 47px; color: firebrick;\"\u003e\u003c\/i\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-darkreader-inline-bgcolor=\"\" style=\"background-color: #eeeeee;\"\u003e\n\u003ctd data-darkreader-inline-border-left=\"\" data-darkreader-inline-border-bottom=\"\" data-darkreader-inline-border-right=\"\" data-darkreader-inline-border-top=\"\" style=\"border: 0px; width: 100%; display: grid; grid-template-columns: 80% 20%; padding: 5px 5px 5px 5px 0px 5px;\"\u003e\u003cspan style=\"padding: 0px 0px 0px 10px; margin: 0px 0px 1px 0px; white-space: nowrap;\"\u003e\u003cstrong\u003eFilter Traces\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-darkreader-inline-border-left=\"\" data-darkreader-inline-border-bottom=\"\" data-darkreader-inline-border-right=\"\" data-darkreader-inline-border-top=\"\" style=\"border: 0px; width: 100%; display: grid; grid-template-columns: 80% 20%; padding: 5px 5px 5px 5px;\"\u003e\n\u003cp data-darkreader-inline-border-left=\"\" data-darkreader-inline-border-bottom=\"\" data-darkreader-inline-border-right=\"\" data-darkreader-inline-border-top=\"\" style=\"margin: 0px 0px 0px 40px; border: none; padding: 0px;\"\u003eImaging Cannula Implantation \u0026amp; Microscope Installation for 2CFM\u003cbr\u003e\u003c\/p\u003e\n\u003ca href=\"https:\/\/doriclenses.com\/downloads\/ApplicationNotes\/2CFM_filter_traces_GFP_RFP_V1.2.pdf\" title=\"Filter Traces GFP-RFP 2-color Microscope\" target=\"_blank\"\u003e \u003ci data-darkreader-inline-color=\"\" class=\"fas fa-file-pdf fa-2x\" style=\"margin: 0 0 0 95px; color: firebrick;\"\u003e\u003c\/i\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Doric Lenses Inc.","offers":[{"title":"Default Title","offer_id":34371447554180,"sku":"","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0306\/2680\/7940\/files\/2CFM_14085428-2c42-4375-a510-276782caf8cd.png?v=1732715364","url":"https:\/\/archive.neuro.doriclenses.com\/products\/2-color-fluorescence-microscopy-system","provider":"Doric Lenses - Archive","version":"1.0","type":"link"}