{"product_id":"efocus-fluorescence-microscope-body","title":"efocus Fluorescence Microscope Body Gen 3","description":"\u003cp\u003e \u003c\/p\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli\u003e\n\u003ca href=\"#tab1\" class=\"active\"\u003eDESCRIPTION\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"#tab2\"\u003eSPECIFICATIONS\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"#tab3\"\u003eSUPPORT\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli id=\"tab1\" class=\"active\"\u003e\n\u003cp\u003eThe 3rd \u003cspan data-mce-fragment=\"1\"\u003egeneration \u003c\/span\u003e\u003cstrong\u003e\u003cspan data-preserver-spaces=\"true\"\u003eefocus Fluorescence Microscope\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-preserver-spaces=\"true\"\u003e enables calcium imaging with cellular resolution over a larger brain area of freely-moving behaving animals. Its field of view has increased to 650 x 650 µm, and the electronic depth adjustment is 300 µm. A more sensitive sensor of the 3rd generation microscope requires less fluorescence excitation light, reducing photobleaching and phototoxicity. The microscope body attaches to the imaging cannula with a simple barrel rotation. No tools are required.\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-preserver-spaces=\"true\"\u003eNotes\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-preserver-spaces=\"true\"\u003e: \u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan data-preserver-spaces=\"true\"\u003e The electrical and optical fiber tethers of an efocus Fluorescence Microscope Body Gen 3 are the same length.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-preserver-spaces=\"true\"\u003e Every microscope body comes with a protective cap.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eThe efocus Fluorescence Microscope Body Gen 3 is only compatible with the Twist-on efocus Imaging Cannulas.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli id=\"tab2\"\u003e\n\u003ctable class=\"table-data-sheet\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e   Field of View\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60%;\"\u003e\u003cspan\u003e 650 µm x 650 µm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e   Working distance adjustment range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cmeta charset=\"UTF-8\"\u003e \u003cspan\u003e0 - 300 µm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e   Frame rate\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026gt; 47 fps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e   Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e 10 mm x 15 mm x 22 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e   Mass\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e 3 g \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e   Computer specifications\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e - Intel Core-i7\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e - 16GB RAM\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e - Gigabit Ethernet, Jumbo frame compatible\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e - Dedicated graphic card \u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #eeeeee;\"\u003e\n\u003cth colspan=\"2\"\u003e\u003cstrong\u003eFluorescence recording\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e   Green fluorescence bodies\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e- Excitation 458 \/ 35 nm\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e- Emission 525 \/ 40 nm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e   Red fluorescence bodies\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e- Excitation 540 \/ 15 nm\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e- Emission 609 \/ 57 nm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #eeeeee;\"\u003e\n\u003cth colspan=\"2\"\u003e\u003cstrong\u003eOptogenetic stimulation*\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e   Green fluorescence bodies\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e- spectral bandwith 612 \/ 69 nm\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e- activation intensity 0 to 55 mW\/mm2\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e   Red fluorescence bodies\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e- spectral bandwith 465 \/ 20 nm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n*Fluorescence + optogenetic microscopes only \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli id=\"tab3\"\u003e\n\u003ctable style=\"width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: rgb(238, 238, 238);\"\u003e\n\u003ctd style=\"border: 0px; width: 100%; display: grid; grid-template-columns: 80% 20%;\"\u003e\u003cspan style=\"padding: 0px 0px 0px 10px; margin: 0px 0px 1px 0px; white-space: nowrap;\"\u003e\u003cstrong\u003eDrawing\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 0px; width: 100%; display: grid; grid-template-columns: 80% 20%; padding: 5px;\"\u003e\n\u003cp style=\"margin: 0px 0px 0px 40px; border: none; padding: 0px;\"\u003eefocus Fluorescence Microscope Body\u003cbr\u003e\u003c\/p\u003e\n\u003ca title=\"efocus Fluorescence Microscope Body Drawing\" href=\"http:\/\/www.doriclenses.com\/downloads\/drawings\/Drawing_eTFMB-L.pdf\" rel=\"noopener\" target=\"_blank\"\u003e\u003ci style=\"margin: 0 0 0 95px; color: firebrick;\" class=\"fas fa-file-pdf fa-2x\"\u003e\u003c\/i\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: rgb(238, 238, 238);\"\u003e\n\u003ctd style=\"border: 0px; width: 100%; display: grid; grid-template-columns: 80% 10% 10%;\"\u003e\n\u003cspan style=\"padding: 0px 0px 0px 10px; margin: 0px 0px 1px 0px; white-space: nowrap;\"\u003e\u003cstrong\u003eUser Manual\u003c\/strong\u003e\u003c\/span\u003e\u003cspan style=\"padding: 0px 0px 0px 10px; margin: 0px 0px 1px 0px; white-space: nowrap; text-align: center;\"\u003e\u003cstrong\u003eFr\u003c\/strong\u003e\u003c\/span\u003e\u003cspan style=\"padding: 0px 0px 0px 10px; margin: 0px 0px 1px 0px; white-space: nowrap; text-align: center;\"\u003e\u003cstrong\u003eEn\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 0px; width: 100%; display: grid; grid-template-columns: 80% 10% 10%;\"\u003e\n\u003cp style=\"margin: 0 0 0 40px; border: none; padding: 0px;\"\u003eefocus Fluorescence Microscope System Gen 3\u003c\/p\u003e\n\u003ca title=\"Manuel utilisateur pour le système de microscopie efocus Gen 3\" href=\"https:\/\/doriclenses.com\/downloads\/UserManual\/UserManual_eTFMB3_eTOSFM3_FR_V1.5.1.pdf\" target=\"_blank\"\u003e\u003ci style=\"margin: 0 0 0 47px; color: #3687ff;\" class=\"fas fa-file-pdf fa-2x\"\u003e\u003c\/i\u003e\u003c\/a\u003e \u003ca title=\"efocus Fluorescence Microscopy System Gen 3 User Manual\" href=\"https:\/\/doriclenses.com\/downloads\/UserManual\/UserManual_eTFMB3_eTOSFM3_V1.5.1.pdf\" target=\"_blank\"\u003e\u003ci style=\"margin: 0 0 0 47px; color: firebrick;\" class=\"fas fa-file-pdf fa-2x\"\u003e\u003c\/i\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: rgb(238, 238, 238);\"\u003e\n\u003ctd style=\"border: 0px; width: 100%; display: grid; grid-template-columns: 80% 10% 10%;\"\u003e\n\u003cspan style=\"padding: 0px 0px 0px 10px; margin: 0px 0px 1px 0px; white-space: nowrap;\"\u003e\u003cstrong\u003eApplication Note\u003c\/strong\u003e\u003c\/span\u003e\u003cspan style=\"padding: 0px 0px 0px 10px; margin: 0px 0px 1px 0px; white-space: nowrap; text-align: center;\"\u003e\u003cstrong\u003eFr\u003c\/strong\u003e\u003c\/span\u003e\u003cspan style=\"padding: 0px 0px 0px 10px; margin: 0px 0px 1px 0px; white-space: nowrap; text-align: center;\"\u003e\u003cstrong\u003eEn\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 0px; width: 100%; display: grid; grid-template-columns: 80% 10% 10%;\"\u003e\n\u003cp style=\"margin: 0 0 0 40px; border: none; padding: 0px;\"\u003eGCaMP configuration filter set\u003cbr\u003e\u003c\/p\u003e\n\u003ca title=\"Note d'application sur la configuration des filtres GCaMP\" href=\"http:\/\/www.doriclenses.com\/downloads\/ApplicationNotes\/ApplicationNote_SFM_filter_Traces_GCaMP_FR_V1.1.pdf\" target=\"_blank\"\u003e\u003ci style=\"margin: 0 0 0 47px; color: #3687ff;\" class=\"fas fa-file-pdf fa-2x\"\u003e\u003c\/i\u003e\u003c\/a\u003e \u003ca title=\"GCaMP configuration filter set Application Note\" href=\"http:\/\/www.doriclenses.com\/downloads\/ApplicationNotes\/ApplicationNote_SFM_filter_Traces_GCaMP_V1.1.pdf\" target=\"_blank\"\u003e\u003ci style=\"margin: 0 0 0 47px; color: firebrick;\" class=\"fas fa-file-pdf fa-2x\"\u003e\u003c\/i\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 0px; width: 100%; display: grid; grid-template-columns: 80% 10% 10%;\"\u003e\n\u003cp style=\"margin: 0 0 0 40px; border: none; padding: 0px;\"\u003eRCaMP2 configuration filter set\u003cbr\u003e\u003c\/p\u003e\n\u003ca title=\"Note d'application sur la configuration des filtres RCaMP2\" href=\"http:\/\/www.doriclenses.com\/downloads\/ApplicationNotes\/ApplicationNote_SFM_filter_Traces_RCaMP_FR_V1.2.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003ci style=\"margin: 0 0 0 47px; color: #3687ff;\" class=\"fas fa-file-pdf fa-2x\"\u003e\u003c\/i\u003e\u003c\/a\u003e \u003ca title=\"RCaMP2 configuration filter set Application Note\" href=\"http:\/\/www.doriclenses.com\/downloads\/ApplicationNotes\/ApplicationNote_SFM_filter_Traces_RCaMP_V1.2.pdf\" target=\"_blank\"\u003e\u003ci style=\"margin: 0 0 0 47px; color: firebrick;\" class=\"fas fa-file-pdf fa-2x\"\u003e\u003c\/i\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 0px; width: 100%; display: grid; grid-template-columns: 80% 10% 10%;\"\u003e\n\u003cp style=\"margin: 0 0 0 40px; border: none; padding: 0px;\"\u003eGCaMP-NpHR3 configuration filter set\u003cbr\u003e\u003c\/p\u003e\n\u003ca title=\"Note d'application sur la configuration des filtres GCaMP-NpHR3\" href=\"http:\/\/www.doriclenses.com\/downloads\/ApplicationNotes\/ApplicationNote_OSFM_filter_Traces_GCaMP_NpHR3_FR_V1.4.pdf\" target=\"_blank\"\u003e\u003ci style=\"margin: 0 0 0 47px; color: #3687ff;\" class=\"fas fa-file-pdf fa-2x\"\u003e\u003c\/i\u003e\u003c\/a\u003e \u003ca title=\"GCaMP-NpHR3 configuration filter set Application Note\" href=\"http:\/\/www.doriclenses.com\/downloads\/ApplicationNotes\/ApplicationNote_OSFM_filter_Traces_GCaMP_NpHR3_V1.4.pdf\" target=\"_blank\"\u003e\u003ci style=\"margin: 0 0 0 47px; color: firebrick;\" class=\"fas fa-file-pdf fa-2x\"\u003e\u003c\/i\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 0px; width: 100%; display: grid; grid-template-columns: 80% 10% 10%;\"\u003e\n\u003cp style=\"margin: 0 0 0 40px; border: none; padding: 0px;\"\u003eGCaMP-ChR2 configuration filter set\u003cbr\u003e\u003c\/p\u003e\n\u003ca title=\"Note d'application sur la configuration des filtres GCaMP-ChR2\" href=\"http:\/\/www.doriclenses.com\/downloads\/ApplicationNotes\/ApplicationNote_OSFM_filter_Traces_RCaMP-ChR2_FR_V1.2.pdf\" target=\"_blank\"\u003e\u003ci style=\"margin: 0 0 0 47px; color: #3687ff;\" class=\"fas fa-file-pdf fa-2x\"\u003e\u003c\/i\u003e\u003c\/a\u003e \u003ca title=\"GCaMP-ChR2 configuration filter set Application Note\" href=\"http:\/\/www.doriclenses.com\/downloads\/ApplicationNotes\/ApplicationNote_OSFM_filter_Traces_RCaMP-ChR2_V1.2.pdf\" target=\"_blank\"\u003e\u003ci style=\"margin: 0 0 0 47px; color: firebrick;\" class=\"fas fa-file-pdf fa-2x\"\u003e\u003c\/i\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Doric Lenses Inc.","offers":[{"title":"Default Title","offer_id":39692191334532,"sku":"","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0306\/2680\/7940\/products\/efocusFluorescenceMicroscopeBodyGen3.jpg?v=1638280878","url":"https:\/\/archive.neuro.doriclenses.com\/products\/efocus-fluorescence-microscope-body","provider":"Doric Lenses - Archive","version":"1.0","type":"link"}