{"product_id":"fiber-optic-liquid-rotary-joints","title":"Fiber-optic \u0026 Liquid Rotary Joints","description":"\u003cscript src=\"https:\/\/kit.fontawesome.com\/8b11cecd5f.js\" crossorigin=\"anonymous\"\u003e\u003c\/script\u003e\n\u003cul class=\"tabs\"\u003e\n    \u003cli\u003e\u003ca class=\"active\" href=\"#tab1\"\u003eDESCRIPTION\u003c\/a\u003e\u003c\/li\u003e\n    \u003cli\u003e\u003ca href=\"#tab2\"\u003eSPECIFICATIONS\u003c\/a\u003e\u003c\/li\u003e\n    \u003cli\u003e\u003ca href=\"#tab3\"\u003eSUPPORT\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n    \u003cli class=\"active\" id=\"tab1\"\u003e\n        \u003cp\u003eThe \u003cb\u003eFiber-optic \u0026amp; liquid rotary joint\u003c\/b\u003e provides a solution to combine optogenetics and simultaneous fluid-delivery in freely-moving animals, minimizing disruptions to animal and reducing the tangling of the tubing and the optic fiber. This rotary joint is designed to work with Doric \u003ca href=\"https:\/\/neuro.doriclenses.com\/collections\/opto-fluid-cannulas\" target=\"_blank\"\u003eopto-fluidic cannula\u003c\/a\u003e to inject drugs or other solutions at the site of optogenetics stimulation, but can also work for subcutaneous injections.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n        \u003cp\u003eThis rotary joint, designed with small core fibers (200µm diameter) and low NA (0.22), is optimized for use with \u003ca href=\"https:\/\/neuro.doriclenses.com\/collections\/laser-diode-illumination\" target=\"_blank\"\u003elasers light sources\u003c\/a\u003e. Contact us to learn if your LED light source will be compatible. In addition, this rotary joint is NOT recommended for fiber photometry applications.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n        \u003cp\u003eOur standard product is provided with 1- channel stainless steel swivel series 375 from Instech Laboratories Inc. If more fluid channels are needed, it can be adapted to work with the 2 or 5 channels fluid swivels. Up to 8 fluid Channels are possible on the rotary joint.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n        \u003cul\u003e\n\u003cb\u003eItems includes :\u003c\/b\u003e\n            \u003cli\u003e1 Optical Rotary Joint (main body)\u003c\/li\u003e\n            \u003cli\u003e1 Single channel stainless steel fluid swivel(\u003ca href=\"https:\/\/www.instechlabs.com\/products\/swivels-mounts\/swivels\/stainless-steel-one-channel\"\u003eInstech model 375\/22 or 375\/25\u003c\/a\u003e)\u003c\/li\u003e\n            \u003cli\u003e1 \u003ca href=\"https:\/\/neuro.doriclenses.com\/products\/mono-fiber-optic-patch-cords\"\u003efiber-optic patch cord\u003c\/a\u003e as per customer preference\u003c\/li\u003e\n            \u003cli\u003e1m of \u003ca href=\"https:\/\/neuro.doriclenses.com\/products\/btcoex\"\u003eco-extruded PE\/PVC tubing\u003c\/a\u003e\n\u003c\/li\u003e\n            \u003cli\u003e2 pre-installed \u003ca href=\"https:\/\/neuro.doriclenses.com\/products\/stainless-tubing-for-hrj-ol\"\u003e stainless tubings\u003c\/a\u003e for fluid delivery through rotary-joint\u003c\/li\u003e\n            \u003cli\u003e+20 additional stainless tubings\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003cbr\u003e\n        \u003cul\u003e\n\u003cb\u003eNotes:\u003c\/b\u003e\n            \u003cli\u003eTo prevent cross-contamination, additional tubings can be ordered separately\u003c\/li\u003e\n        \u003c\/ul\u003e   \n    \u003c\/li\u003e\n    \u003cli id=\"tab2\"\u003e\n        \u003ctable class=\"table-data-sheet\"\u003e\n            \u003ctbody\u003e\n                \u003ctr class=\"odd\"\u003e\n                    \u003ctd\u003e\n                        \u003cstrong\u003eOptical Fiber\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003edesigned to use with 200 µm core - NA 0.22\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr class=\"even\"\u003e\n                    \u003ctd\u003e\n                        \u003cstrong\u003eTransmission\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e60% \u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr class=\"odd\"\u003e\n                    \u003ctd\u003e\n                        \u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTransmission Variation\u003c\/strong\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e± 5 % in rotation \u003cbr\u003e- 10% drop when tubing crosses light path\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr class=\"odd\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eWavelength Range\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e450 - 650 nm\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr class=\"even\"\u003e\n                    \u003ctd\u003e\n                        \u003cstrong\u003eStart up torque\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e150 μN*m without fluid swivel\u003cbr\u003e600 μN*m with 1-channel fluid swivel\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n    \u003c\/li\u003e\n    \u003cli id=\"tab3\"\u003e\n        \u003ctable style=\"width: 100%;\"\u003e\n            \u003ctbody\u003e\n                \u003ctr style=\"background-color: #eeeeee;\"\u003e\n                    \u003ctd style=\"border: 0px; width: 100%; display: grid; grid-template-columns: 80% 20%; padding: 5px 5px 5px 5px 0px 5px;\"\u003e\u003cspan style=\"padding: 0px 0px 0px 10px; margin: 0px 0px 1px 0px; white-space: nowrap;\"\u003e\u003cstrong\u003eDrawing\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd style=\"border: 0px; width: 100%; display: grid; grid-template-columns: 80% 20%; padding: 5px 5px 5px 5px;\"\u003e\n                        \u003cp style=\"margin: 0px 0px 0px 40px; border: none; padding: 0px;\"\u003eFiber-optic \u0026amp; Liquid Rotary Joints\u003c\/p\u003e\n                        \u003ca href=\"https:\/\/doriclenses.com\/downloads\/drawings\/Drawing_HRJ-OL.pdf\" title=\"Fiber-optic \u0026amp; Liquid Rotary Joints Drawing\" target=\"_blank\"\u003e\u003ci class=\"fas fa-file-pdf fa-2x\" style=\"margin: 0 0 0 95px; color: firebrick;\"\u003e\u003c\/i\u003e\u003c\/a\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #eeeeee;\"\u003e\n                    \u003ctd style=\"border: 0px; width: 100%; display: grid; grid-template-columns: 80% 10% 10%; padding: 5px 5px 5px 5px 0px 5px;\"\u003e\n                        \u003cspan style=\"padding: 0px 0px 0px 10px; margin: 0px 0px 1px 0px; white-space: nowrap;\"\u003e\u003cstrong\u003eUser Manual\u003c\/strong\u003e\u003c\/span\u003e\u003cspan style=\"padding: 0px 0px 0px 10px; margin: 0px 0px 1px 0px; white-space: nowrap; text-align: center;\"\u003e\u003cstrong\u003eFr\u003c\/strong\u003e\u003c\/span\u003e\u003cspan style=\"padding: 0px 0px 0px 10px; margin: 0px 0px 1px 0px; white-space: nowrap; text-align: center;\"\u003e\u003cstrong\u003eEn\u003c\/strong\u003e\u003c\/span\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd style=\"border: 0px; width: 100%; display: grid; grid-template-columns: 80% 10% 10%; padding: 5px 5px 5px 5px 0px 5px;\"\u003e\n                        \u003cp style=\"margin: 0 0 0 40px; border: none; padding: 0px;\"\u003eFiber-optic \u0026amp; Liquid Rotary Joint\u003c\/p\u003e\n                        \u003ca href=\"https:\/\/doriclenses.com\/downloads\/UserManual\/UserManual_HRJOL_FR_V1.0.1.pdf\" title=\"Manuel utilisateur pour le Joint rotatif à fibre optique et liquide\" target=\"_blank\"\u003e\u003ci class=\"fas fa-file-pdf fa-2x\" style=\"margin: 0 0 0 47px; color: #3687ff\"\u003e\u003c\/i\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/doriclenses.com\/downloads\/UserManual\/UserManual_HRJOL_V1.0.1.pdf\" title=\"Fiber-optic \u0026amp; Liquid Rotary Joint User Manual\" target=\"_blank\"\u003e\u003ci class=\"fas fa-file-pdf fa-2x\" style=\"margin: 0 0 0 47px; color: firebrick;\"\u003e\u003c\/i\u003e\u003c\/a\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n    \u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Doric Lenses Inc.","offers":[{"title":"Default Title","offer_id":32158746869892,"sku":"","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0306\/2680\/7940\/products\/HRJ-OL.jpg?v=1592237100","url":"https:\/\/archive.neuro.doriclenses.com\/products\/fiber-optic-liquid-rotary-joints","provider":"Doric Lenses - Archive","version":"1.0","type":"link"}