{"product_id":"opto-electric-cannulas","title":"Optoelectric Cannulas - single electrode","description":"\u003cscript crossorigin=\"anonymous\" src=\"https:\/\/kit.fontawesome.com\/8b11cecd5f.js\"\u003e\u003c\/script\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli\u003e\u003ca href=\"#tab1\" class=\"active\"\u003eDESCRIPTION\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"#tab2\"\u003eELECTRODE TABLE\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"#tab5\"\u003eFIBER TIP\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"#tab4\"\u003eSUPPORT\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli id=\"tab1\" class=\"active\"\u003e\n\u003cp\u003eThe most straightforward configuration comprises a single 200 µm core diameter optical fiber of 0.22 NA and a 75 µm diameter metallic wire of 3MΩ impedance as an electrode. A grooved 1.25 mm zirconia ferrule has optical fiber in its central hole and the electrode embedded in its groove. The contacts with corresponding optoelectric patchcord are maintained with a bronze sleeve.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eOther optical fiber, electrode types and multiple electrodes or even multiple fiber configurations are available upon request.\u003c\/p\u003e\n\u003cspan\u003e\u003cstrong\u003eNotes\u003c\/strong\u003e:\u003c\/span\u003e\n\u003cul style=\"list-style: disc;\"\u003e\n\u003cli\u003eThe electrode protrusion is the distance (mm) between the fiber tip and the electrode tip. Positive protrusion indicates the electrode is more prolonged than optical fiber.\u003c\/li\u003e\n\u003cli\u003eStereotaxic Cannula Holders and Ferrule Receptacle adapters are available for implantation to secure the Mono Optoelectric Cannulas (\u003cstrong\u003eSCH\u003c\/strong\u003e and \u003cstrong\u003eFCA\u003c\/strong\u003e).\u003c\/li\u003e\n\u003cli\u003eMore information on our electrodes can be found in this document (\u003ca href=\"http:\/\/www.doriclenses.com\/downloads\/ApplicationNotes\/OEC%20Cannula%20electrodes.pdf\"\u003ePDF\u003c\/a\u003e).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli id=\"tab2\"\u003e\n\u003ctable height=\"35\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"35%\"\u003e\u003cstrong\u003eDESCRIPTION\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"20%\"\u003e\u003cstrong\u003eImpedance\u003cbr\u003e(Ohm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"35%\"\u003e\u003cstrong\u003eRECOMMENDED USE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"10%\"\u003e\u003cstrong\u003eCODE\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e 50 µm tungsten wire with flat tip\u003c\/td\u003e\n\u003ctd\u003e 0.1 to 0.5 M\u003c\/td\u003e\n\u003ctd\u003e LFP\u003c\/td\u003e\n\u003ctd\u003eW50-FLT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e 50 µm tungsten wire with 45 deg angled tip\u003c\/td\u003e\n\u003ctd\u003e 0.1 to 0.5 M\u003c\/td\u003e\n\u003ctd\u003e LFP\u003c\/td\u003e\n\u003ctd\u003eW50-A45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"8\"\u003e 75 µm tungsten wire with tapered tip\u003c\/td\u003e\n\u003ctd\u003e 0.1 M\u003c\/td\u003e\n\u003ctd\u003e LFP\u003c\/td\u003e\n\u003ctd\u003e0.1M-75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e 0.5 M\u003c\/td\u003e\n\u003ctd\u003e LFP\u003c\/td\u003e\n\u003ctd\u003e0.5M-75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e 1.0 M\u003c\/td\u003e\n\u003ctd\u003e Multi unit\u003c\/td\u003e\n\u003ctd\u003e1.0M-75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e 1.5 M\u003c\/td\u003e\n\u003ctd\u003e Multi unit\u003c\/td\u003e\n\u003ctd\u003e1.5M-75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e 2.0 M\u003c\/td\u003e\n\u003ctd\u003e Single and Multi unit\u003c\/td\u003e\n\u003ctd\u003e2.0M-75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e 2.5 M\u003c\/td\u003e\n\u003ctd\u003e Single and Multi unit\u003c\/td\u003e\n\u003ctd\u003e2.5M-75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e 3.0 M\u003c\/td\u003e\n\u003ctd\u003e Single unit\u003c\/td\u003e\n\u003ctd\u003e3.0M-75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e 5.0 M\u003c\/td\u003e\n\u003ctd\u003e Single unit\u003c\/td\u003e\n\u003ctd\u003e5.0M-75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"8\"\u003e 125 µm tungsten wire with tapered tip\u003c\/td\u003e\n\u003ctd\u003e 0.1 M\u003c\/td\u003e\n\u003ctd\u003e Deep Chronic implant, LFP\u003c\/td\u003e\n\u003ctd\u003e0.1M-125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e 0.5 M\u003c\/td\u003e\n\u003ctd\u003e Deep Chronic implant, LFP\u003c\/td\u003e\n\u003ctd\u003e0.5M-125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e 1.0 M\u003c\/td\u003e\n\u003ctd\u003e Deep Chronic implant, Multi unit\u003c\/td\u003e\n\u003ctd\u003e1.0M-125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e 1.5 M\u003c\/td\u003e\n\u003ctd\u003e Deep Chronic implant, Multi unit\u003c\/td\u003e\n\u003ctd\u003e1.5M-125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e 2.0 M\u003c\/td\u003e\n\u003ctd\u003e Deep Chronic implant, Single and Multi unit\u003c\/td\u003e\n\u003ctd\u003e2.0M-125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e 2.5 M\u003c\/td\u003e\n\u003ctd\u003e Deep Chronic implant, Single and Multi unit\u003c\/td\u003e\n\u003ctd\u003e2.5M-125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e 3.0 M\u003c\/td\u003e\n\u003ctd\u003e Deep Chronic implant, Single unit\u003c\/td\u003e\n\u003ctd\u003e3.0M-125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e 5.0 M\u003c\/td\u003e\n\u003ctd\u003e Deep Chronic implant, Single unit\u003c\/td\u003e\n\u003ctd\u003e5.0M-125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/li\u003e\n\u003cli id=\"tab5\"\u003e\n\u003ca href=\"http:\/\/doriclenses.com\/downloads\/ApplicationNotes\/ApplicationNote_Illumination_FiberTip_V1.0.0.pdf\"\u003e\n\u003cdiv style=\"text-align: right;\"\u003e\u003cimg width=\"400\" src=\"https:\/\/doriclenses.com\/downloads\/Website\/fiber_tip\/Fiber-Simulation-preview1.png\" alt=\"Click to download the Application Note\" style=\"float: right;\"\u003e\u003c\/div\u003e\n\u003c\/a\u003e\u003cspan\u003e\u003cbr\u003e\u003cbr\u003eThe light propagation into brain tissue will vary with the optical fiber type and the light source parameters.  It can be visualized in this \u003c\/span\u003e\u003ca href=\"http:\/\/doriclenses.com\/downloads\/ApplicationNotes\/ApplicationNote_Illumination_FiberTip_V1.0.0.pdf\"\u003eApplication Note\u003c\/a\u003e\u003cspan data-mce-fragment=\"1\"\u003e (the French version is available \u003c\/span\u003e\u003ca href=\"http:\/\/doriclenses.com\/downloads\/ApplicationNotes\/ApplicationNote_Illumination_FiberTip_FR_V1.0.0.pdf\"\u003ehere\u003c\/a\u003e\u003cspan data-mce-fragment=\"1\"\u003e).\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e \u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e \u003cbr\u003e\n\u003ctable width=\"100%\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 29.5557%; text-align: center;\" data-mce-fragment=\"1\" data-mce-style=\"width: 29.5557%; text-align: center;\"\u003e\u003cstrong\u003eDrawing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 18%; text-align: center;\" data-mce-fragment=\"1\" data-mce-style=\"width: 18%; text-align: center;\"\u003e\u003cstrong\u003eCode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 18%; text-align: center;\" data-mce-fragment=\"1\" data-mce-style=\"width: 18%; text-align: center;\"\u003e\u003cstrong\u003eNote\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 25.4443%; text-align: center;\" data-mce-fragment=\"1\" data-mce-style=\"width: 25.4443%; text-align: center;\"\u003eFlat Tip\u003c\/td\u003e\n\u003ctd style=\"width: 29.5557%; text-align: center;\" data-mce-fragment=\"1\" data-mce-style=\"width: 29.5557%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/doriclenses.com\/downloads\/Website\/fiber_tip\/FLT_tip.png\" width=\"200\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 18%; text-align: center;\" data-mce-fragment=\"1\" data-mce-style=\"width: 18%; text-align: center;\"\u003eFLT\u003c\/td\u003e\n\u003ctd style=\"width: 18%; text-align: center;\" data-mce-fragment=\"1\" data-mce-style=\"width: 18%; text-align: center;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 25.4443%; text-align: center;\" data-mce-fragment=\"1\" data-mce-style=\"width: 25.4443%; text-align: center;\"\u003eConical Tip\u003c\/td\u003e\n\u003ctd style=\"width: 29.5557%; text-align: center;\" data-mce-fragment=\"1\" data-mce-style=\"width: 29.5557%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/doriclenses.com\/downloads\/Website\/fiber_tip\/C60_tip.png\" width=\"200\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 18%; text-align: center;\" data-mce-fragment=\"1\" data-mce-style=\"width: 18%; text-align: center;\"\u003e\n\u003cp\u003eC45\u003c\/p\u003e\n\u003cp\u003eC60\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 18%; text-align: left;\" data-mce-fragment=\"1\" data-mce-style=\"width: 18%; text-align: left;\"\u003e\n\u003cp\u003eRounded tip thickness: ~0.1x to 0.2x core diameter\u003c\/p\u003e\n\u003cp\u003eStandard angles: 45\u003cspan data-mce-fragment=\"1\"\u003e°, \u003c\/span\u003e 60°\u003c\/p\u003e\n\u003cp\u003eOther angles on request (max 60°)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eTaper Tip\u003c\/td\u003e\n\u003ctd\u003e\u003cimg src=\"https:\/\/doriclenses.com\/downloads\/Website\/fiber_tip\/TAPER_tip.png\" width=\"200\"\u003e\u003c\/td\u003e\n\u003ctd\u003eTAPER \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/li\u003e\n\u003cli id=\"tab4\"\u003e\n\u003ctable style=\"width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #eeeeee;\"\u003e\n\u003ctd style=\"border: 0px; width: 100%; display: grid; grid-template-columns: 80% 20%; padding: 5px 5px 5px 5px 0px 5px;\"\u003e\u003cspan style=\"padding: 0px 0px 0px 10px; margin: 0px 0px 1px 0px; white-space: nowrap;\"\u003e\u003cstrong\u003eDrawing\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 0px; width: 100%; display: grid; grid-template-columns: 80% 20%; padding: 5px 5px 5px 5px;\"\u003e\n\u003cp style=\"margin: 0px 0px 0px 40px; border: none; padding: 0px;\"\u003eOptoelectric Cannulas ZF1.25\u003c\/p\u003e\n\u003ca href=\"https:\/\/doriclenses.com\/downloads\/drawings\/Drawing_OEC_ZF1.25.pdf\" title=\"Optoelectric Cannulas ZF1.25 Drawing\" target=\"_blank\"\u003e\u003ci class=\"fas fa-file-pdf fa-2x\" style=\"margin: 0 0 0 95px; color: firebrick;\"\u003e\u003c\/i\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #eeeeee;\"\u003e\n\u003ctd style=\"border: 0px; width: 100%; display: grid; grid-template-columns: 80% 10% 10%; padding: 5px 5px 5px 5px 0px 5px;\"\u003e\n\u003cspan style=\"padding: 0px 0px 0px 10px; margin: 0px 0px 1px 0px; white-space: nowrap;\"\u003e\u003cstrong\u003eBrochure\u003c\/strong\u003e\u003c\/span\u003e\u003cspan style=\"padding: 0px 0px 0px 10px; margin: 0px 0px 1px 0px; white-space: nowrap; text-align: center;\"\u003e\u003cstrong\u003eFr\u003c\/strong\u003e\u003c\/span\u003e\u003cspan style=\"padding: 0px 0px 0px 10px; margin: 0px 0px 1px 0px; white-space: nowrap; text-align: center;\"\u003e\u003cstrong\u003eEn\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 0px; width: 100%; display: grid; grid-template-columns: 80% 10% 10%; padding: 5px 5px 5px 5px 0px 5px;\"\u003e\n\u003cp style=\"margin: 0 0 0 40px; border: none; padding: 0px;\" data-mce-style=\"margin: 0 0 0 40px; border: none; padding: 0px;\"\u003eCustom optical fiber and electrode configurations\u003c\/p\u003e\n\u003ca href=\"https:\/\/doriclenses.com\/downloads\/documents\/Brochure_OEC_Cannula_electrodes_FR_V1.1.pdf\" title=\"Brochure Configurations personnalisées de fibres optiques et d'électrodes\" target=\"_blank\"\u003e\u003ci class=\"fas fa-file-pdf fa-2x\" style=\"margin: 0 0 0 47px; color: #3687ff;\"\u003e\u003c\/i\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/doriclenses.com\/downloads\/documents\/Brochure_OEC_Cannula_electrodes_V1.1.pdf\" title=\"Custom optical fiber and electrode configurations Brochure\" target=\"_blank\"\u003e\u003ci class=\"fas fa-file-pdf fa-2x\" style=\"margin: 0 0 0 47px; color: firebrick;\"\u003e\u003c\/i\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Doric Lenses Inc.","offers":[{"title":"Default Title","offer_id":32766213718148,"sku":"","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0306\/2680\/7940\/products\/opto-electric-cannulas.jpg?v=1613425562","url":"https:\/\/archive.neuro.doriclenses.com\/products\/opto-electric-cannulas","provider":"Doric Lenses - Archive","version":"1.0","type":"link"}