{"product_id":"opto-fluid-cannula-with-interchangeable-injectors","title":"Optofluid Cannula with interchangeable injectors","description":"\u003cscript src=\"https:\/\/kit.fontawesome.com\/8b11cecd5f.js\" crossorigin=\"anonymous\"\u003e\u003c\/script\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli\u003e\u003ca class=\"active\" href=\"#tab1\"\u003eDESCRIPTION\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"#tab2\"\u003eSPECIFICATION\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"#tab3\"\u003eGUIDING TUBE CODES\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"#tab4\"\u003eSUPPORT\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\" id=\"tab1\"\u003e\n\u003cp\u003eThe Optofluid Cannula with interchangeable injectors (iOFC) provides a simple way to use both light and fluid injection when they are not required at the same time. The interchangeable configuration saves space and weight and can be used with optical and fluid injector of different lengths. The threaded body ensures a secure connection for the injectors.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eEach cannula ships with a plug to prevent the guiding tube from clogging at implantation and between uses. Since both the optical and fluid injector does not stay inside the brain for a prolonged time, the plug is placed back when the cannula is not in use to keep it free of biological debris.\u003c\/p\u003e\n\u003cspan\u003e\u003cstrong\u003eNOTES:\u003c\/strong\u003e\u003c\/span\u003e\n\u003cul style=\"list-style: disc;\"\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/optical-injector-iofc\" target=\"_blank\"\u003e\u003cstrong\u003eOptical Injector\u003c\/strong\u003e\u003c\/a\u003e and \u003ca href=\"\/products\/fluid-injector-iofc\" target=\"_blank\"\u003e\u003cstrong\u003eFluid Injector\u003c\/strong\u003e\u003c\/a\u003e must be ordered separately.\u003c\/li\u003e\n\u003cli\u003eThe tubing internal diameter must match the optical injector external diameter (see the tables in section GUIDING TUBE CODES).\u003c\/li\u003e\n\u003cli\u003eA Stereotaxic Cannula Holder is available for implantation to secure the Optofluid Cannula with interchangeable injectors. The plug (included with the cannula) is used to fix the holder on the Optofluid Cannula\u003cstrong\u003e\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eA 2-meter length of polyethylene tube is sold separately to connect a fluid delivery system to the cannula\u003cstrong\u003e\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli id=\"tab2\"\u003e\n\u003ctable class=\"table-data-sheet\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"even\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOptical Transmission\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e \u0026gt; 80 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFluid Connector\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e Stainless tube 485 µm OD \u003cbr\u003e (compatible with 25ga tubing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cstrong\u003eFluid Tubing ID\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eGlass\u003c\/td\u003e\n\u003ctd\u003e100 µm inner diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003ctd colspan=\"2\"\u003ePolyimide\u003c\/td\u003e\n\u003ctd\u003e140 µm inner diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003ctd rowspan=\"4\"\u003e\u003cstrong\u003eInjector Dead Volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003eM3\u003c\/td\u003e\n\u003ctd\u003eGlass\u003c\/td\u003e\n\u003ctd\u003e130 nL + 8 nL \/ mm fiber length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003ctd\u003ePolyimide\u003c\/td\u003e\n\u003ctd\u003e245 nL + 15.4 nL \/ mm fiber length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003ctd rowspan=\"2\"\u003eZF\u003c\/td\u003e\n\u003ctd\u003eGlass\u003c\/td\u003e\n\u003ctd\u003e125 nL + 8 nL \/ mm fiber length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003ctd\u003ePolyimide\u003c\/td\u003e\n\u003ctd\u003e240 nL + 15.4 nL \/ mm fiber length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003ctd\u003e\u003cstrong\u003eBase Dimension\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003esee drawing\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/li\u003e\n\u003cli id=\"tab3\"\u003e\n\u003cbr\u003e\n\u003ctable cellspacing=\"0\" border=\"1\" align=\"center\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #eeeeee;\"\u003e\n\u003ctd colspan=\"1\" style=\"text-align: center; min-width: 50px; width: 150px; padding: 5px; margin: 0px;\"\u003e\n\u003cstrong\u003eOptical Injector\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"min-width: 50px; width: 150px; text-align: center; padding: 5px; margin: 0px;\"\u003e\u003cstrong\u003eGuiding Tube\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd rowspan=\"2\" style=\"min-width: 50px; width: 180px; text-align: center; padding: 5px; margin: 0px; color: red;\"\u003e\u003cstrong\u003eGuiding Tube Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #eeeeee; border-top: 1px solid grey;\"\u003e\n\u003ctd style=\"min-width: 50px; width: 150px; text-align: center; padding: 5px; margin: 0px;\" colspan=\"1\"\u003e\n\u003cstrong\u003eOuter Diameter\u003cbr\u003e( μm ) \u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"min-width: 50px; width: 150px; text-align: center; padding: 5px; margin: 0px;\"\u003e\n\u003cstrong\u003eInner Diameter\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e( μm )\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"min-width: 50px; width: 150px; text-align: center; padding: 5px; margin: 0px;\"\u003e\n\u003cstrong\u003eOuter Diameter \u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e( μm )\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"min-width: 50px; text-align: center; padding: 0px; margin: 0px;\"\u003e70 to 125\u003c\/td\u003e\n\u003ctd style=\"min-width: 50px; text-align: center; padding: 0px; margin: 0px;\"\u003e250\u003c\/td\u003e\n\u003ctd style=\"min-width: 50px; text-align: center; padding: 0px; margin: 0px;\"\u003e350\u003c\/td\u003e\n\u003ctd style=\"min-width: 50px; text-align: center; padding: 0px; margin: 0px;\"\u003e\u003cstrong\u003e250\/350\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"min-width: 50px; text-align: center; padding: 0px; margin: 0px;\"\u003e230 to 250\u003c\/td\u003e\n\u003ctd style=\"min-width: 50px; text-align: center; padding: 0px; margin: 0px;\"\u003e320\u003c\/td\u003e\n\u003ctd style=\"min-width: 50px; text-align: center; padding: 0px; margin: 0px;\"\u003e430\u003c\/td\u003e\n\u003ctd style=\"min-width: 50px; text-align: center; padding: 0px; margin: 0px;\"\u003e\u003cstrong\u003e320\/430\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"min-width: 50px; text-align: center; padding: 0px; margin: 0px;\"\u003e360 to 500\u003c\/td\u003e\n\u003ctd style=\"min-width: 50px; text-align: center; padding: 0px; margin: 0px;\"\u003e530\u003c\/td\u003e\n\u003ctd style=\"min-width: 50px; text-align: center; padding: 0px; margin: 0px;\"\u003e660\u003c\/td\u003e\n\u003ctd style=\"min-width: 50px; text-align: center; padding: 0px; margin: 0px;\"\u003e\u003cstrong\u003e530\/660\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli id=\"tab4\"\u003e\n\u003ctable style=\"width: 100%;\" data-mce-style=\"width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #eeeeee;\" data-mce-style=\"background-color: #eeeeee;\"\u003e\n\u003ctd style=\"border: 0px; width: 100%; display: grid; grid-template-columns: 80% 20%; padding: 5px 5px 5px 5px 0px 5px;\" data-mce-style=\"border: 0px; width: 100%; display: grid; grid-template-columns: 80% 20%; padding: 5px 5px 5px 5px 0px 5px;\"\u003e\u003cspan style=\"padding: 0px 0px 0px 10px; margin: 0px 0px 1px 0px; white-space: nowrap;\" data-mce-style=\"padding: 0px 0px 0px 10px; margin: 0px 0px 1px 0px; white-space: nowrap;\"\u003e\u003cstrong\u003eDrawing\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 0px; width: 100%; display: grid; grid-template-columns: 80% 20%; padding: 5px 5px 5px 5px;\"\u003e\n\u003cp style=\"margin: 0px 0px 0px 40px; border: none; padding: 0px;\"\u003eOptofluid Cannula with interchangeable injectors SM3\u003c\/p\u003e\n\u003ca href=\"https:\/\/doriclenses.com\/downloads\/drawings\/Drawing_iOFC_M3.pdf\" title=\"Optofluid Cannula with interchangeable injectors SM3 Drawing\" target=\"_blank\"\u003e\u003ci class=\"fas fa-file-pdf fa-2x\" style=\"margin: 0 0 0 95px; color: firebrick;\"\u003e\u003c\/i\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 0px; width: 100%; display: grid; grid-template-columns: 80% 20%; padding: 5px 5px 5px 5px;\"\u003e\n\u003cp style=\"margin: 0px 0px 0px 40px; border: none; padding: 0px;\"\u003eOptofluid Cannula with interchangeable injectors ZF1.25\u003c\/p\u003e\n\u003ca href=\"https:\/\/doriclenses.com\/downloads\/drawings\/Drawing_iOFC_ZF.pdf\" title=\"Optofluid Cannula with interchangeable injectors ZF1.25 Drawing\" target=\"_blank\"\u003e\u003ci class=\"fas fa-file-pdf fa-2x\" style=\"margin: 0 0 0 95px; color: firebrick;\"\u003e\u003c\/i\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #eeeeee;\"\u003e\n\u003ctd style=\"border: 0px; width: 100%; display: grid; grid-template-columns: 80% 10% 10%; padding: 5px 5px 5px 5px 0px 5px;\"\u003e\n\u003cspan style=\"padding: 0px 0px 0px 10px; margin: 0px 0px 1px 0px; white-space: nowrap;\"\u003e\u003cstrong\u003eUser Manual\u003c\/strong\u003e\u003c\/span\u003e\u003cspan style=\"padding: 0px 0px 0px 10px; margin: 0px 0px 1px 0px; white-space: nowrap; text-align: center;\"\u003e\u003cstrong\u003eFr\u003c\/strong\u003e\u003c\/span\u003e\u003cspan style=\"padding: 0px 0px 0px 10px; margin: 0px 0px 1px 0px; white-space: nowrap; text-align: center;\"\u003e\u003cstrong\u003eEn\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 0px; width: 100%; display: grid; grid-template-columns: 80% 10% 10%; padding: 5px 5px 5px 5px 0px 5px;\"\u003e\n\u003cp style=\"margin: 0 0 0 40px; border: none; padding: 0px;\"\u003eOptofluid Cannulas Implantation and Fluid Injection\u003c\/p\u003e\n\u003ca title=\"Manuel utilisateur pour l'implantation de canules optofluides et l'injection de liquide\" href=\"https:\/\/doriclenses.com\/downloads\/UserManual\/UserManual_OFC_FR_V1.0.0.pdf\" target=\"_blank\"\u003e\u003ci style=\"margin: 0 0 0 47px; color: #3687ff;\" class=\"fas fa-file-pdf fa-2x\"\u003e\u003c\/i\u003e\u003c\/a\u003e \u003ca title=\"Optofluid Cannulas Implantation and Fluid Injection User Manual\" href=\"https:\/\/doriclenses.com\/downloads\/UserManual\/UserManual_OFC_V1.0.0.pdf\" target=\"_blank\"\u003e\u003ci style=\"margin: 0 0 0 47px; color: firebrick;\" class=\"fas fa-file-pdf fa-2x\"\u003e\u003c\/i\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Doric Lenses Inc.","offers":[{"title":"Default Title","offer_id":32790188916868,"sku":"","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0306\/2680\/7940\/products\/opto-fluid-cannula-with-interchangeable-injectors.jpg?v=1611202371","url":"https:\/\/archive.neuro.doriclenses.com\/products\/opto-fluid-cannula-with-interchangeable-injectors","provider":"Doric Lenses - Archive","version":"1.0","type":"link"}