{"product_id":"snap-in-surface-fluorescence-microscopy-systems","title":"Snap-in Surface Fluorescence Microscopy systems","description":"\u003cp\u003e \u003c\/p\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli\u003e\u003ca class=\"active\" href=\"#tab1\"\u003eDESCRIPTION\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"#tab2\"\u003eGCaMP\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"#tab3\"\u003eRed Fluo\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"#tab4\"\u003eGCaMP + Red Opsin\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"#tab5\"\u003eRed Fluo + CHR2\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"#tab6\"\u003eSUPPORT\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli id=\"tab1\" class=\"active\"\u003e\n\u003cp\u003eSurface snap-in microscopy systems are optimized to image brain structures up to 150 um deep without using invasive implants. As no GRIN lenses are being used, the image quality of surface microscopes is higher.\u003c\/p\u003e\nMotor assisted rotary joint (AHRJ) and microscope dummy are available on option.\u003c\/li\u003e\n\u003cli id=\"tab2\"\u003eThe GCaMP surface microscopy system is optimized for GFP-like fluorescence proteins imaging. \u003cbr\u003e\u003cbr\u003eThe system includes: \u003cbr\u003e\u003cspan style=\"float: right; padding-right: 10px;\"\u003e \u003cimg width=\"400\" style=\"float: right;\" alt=\"\" src=\"https:\/\/doriclenses.com\/downloads\/Website\/SFMS-GCaMP-2-20.jpg\"\u003e \u003c\/span\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/snap-in-fluorescence-microscope-bodies-model-s\" target=\"_blank\"\u003eSnap-in Green Fluorescence Microscope Body, Model S\u003c\/a\u003e, the head mounted microscope\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/fluorescence-microscope-driver\" target=\"_blank\"\u003eFluorescence Microscope Driver\u003c\/a\u003e, to control the microscope\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/connectorized-led-1\" target=\"_blank\"\u003eConnectorized LED\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003eOptical fiber patch cords, to connect the light source to the microscope\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/fluorescence-microscope-holder?\" target=\"_blank\"\u003eFluorescence Microscope Holder\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/clamp-for-fluorescence-microscope-holder\" target=\"_blank\"\u003eClamp for Fluorescence Microscope Holder\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/doric-neuroscience-studio\" target=\"_blank\"\u003eDoric Neuroscience Studio\u003c\/a\u003e Software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003eAdd optional items:\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/assisted-1x1-pigtailed-fiber-optic-electric-rotary-joints-24-contacts?\" target=\"_blank\"\u003eAssisted 1x1 Pigtailed Fiber-optic \u0026amp; Electric Rotary Joint - 24 contacts\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/dummy-microscope?\" target=\"_blank\"\u003eSnap-in Microscope Dummy, Model S\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/neuro.doriclenses.com\/collections\/behavior-camera\/products\/behavior-camera\"\u003eBehavior Camera\u003c\/a\u003e to record animal behavior\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/neuro.doriclenses.com\/products\/computeur?_pos=1\u0026amp;_sid=200a6c079\u0026amp;_ss=r\u0026amp;productoption%5BWorkstation%3A%5D=High%20performance\"\u003eWorkstation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/neuro.doriclenses.com\/products\/danse\"\u003edanse™\u003c\/a\u003e analyzing software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003eComplete your system with:\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/snap-in-imaging-cannula-model-s\" target=\"_blank\"\u003eSnap-in Imaging Cannula, Model S\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/protrusion-adjustment-ring-set\" target=\"_blank\"\u003eProtrusion Adjustment Ring Set Model S\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003ctable class=\"table-data-sheet\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e   Field of View\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60%;\"\u003e\u003cspan\u003e 700 µm x 700 µm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e   Working distance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cmeta charset=\"UTF-8\"\u003e \u003cspan\u003e1.1 mm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e   Frame rate\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026gt; 45 fps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003e\u003cstrong\u003eFluorescence recording\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e   Excitation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e458 \/ 35 nm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e   Emission\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e525 \/ 40 nm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/li\u003e\n\u003cli id=\"tab3\"\u003eThe RCaMP surface microscopy system is optimized for RFP-like fluorescence proteins imaging. \u003cbr\u003e\u003cbr\u003eThe system includes: \u003cbr\u003e\u003cspan style=\"float: right; padding-right: 10px;\"\u003e \u003cimg width=\"400\" style=\"float: right;\" alt=\"\" src=\"https:\/\/doriclenses.com\/downloads\/Website\/SFMS-Red-Fluo-2-20.jpg\"\u003e \u003c\/span\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/snap-in-fluorescence-microscope-bodies-model-s\" target=\"_blank\"\u003eSnap-in Red Fluorescence Microscope Body, Model S\u003c\/a\u003e, the head mounted microscope\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/fluorescence-microscope-driver\" target=\"_blank\"\u003eFluorescence Microscope Driver\u003c\/a\u003e, to control the microscope\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/liser-led-fiber-light-source?\"\u003e★LISER™ Light Source\u003c\/a\u003e with \u003ca href=\"\/products\/liser-bandpass-filters?\" target=\"_blank\"\u003e540\/15 nm bandpass filter\u003c\/a\u003e for Red Fluoescent Proteins excitation\u003c\/li\u003e\n\u003cli\u003eOptical fiber patch cords, to connect the light source to the microscope\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/fluorescence-microscope-holder?\" target=\"_blank\"\u003eFluorescence Microscope Holder\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/clamp-for-fluorescence-microscope-holder\" target=\"_blank\"\u003eClamp for Fluorescence Microscope Holder\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/doric-neuroscience-studio\" target=\"_blank\"\u003eDoric Neuroscience Studio\u003c\/a\u003e Software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003eAdd optional items:\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/assisted-1x1-pigtailed-fiber-optic-electric-rotary-joints-24-contacts?\" target=\"_blank\"\u003eAssisted 1x1 Pigtailed Fiber-optic \u0026amp; Electric Rotary Joint - 24 contacts\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/dummy-microscope?\" target=\"_blank\"\u003eSnap-in Microscope Dummy, Model S\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/neuro.doriclenses.com\/collections\/behavior-camera\/products\/behavior-camera\"\u003eBehavior Camera\u003c\/a\u003e to record animal behavior\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/neuro.doriclenses.com\/products\/computeur?_pos=1\u0026amp;_sid=200a6c079\u0026amp;_ss=r\u0026amp;productoption%5BWorkstation%3A%5D=High%20performance\"\u003eWorkstation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/neuro.doriclenses.com\/products\/danse\"\u003edanse™\u003c\/a\u003e analyzing software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003eComplete your system with:\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/snap-in-imaging-cannula-model-s\" target=\"_blank\"\u003eSnap-in Imaging Cannula, Model S\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/protrusion-adjustment-ring-set\" target=\"_blank\"\u003eProtrusion Adjustment Ring Set Model S\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003ctable class=\"table-data-sheet\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e   Field of View\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60%;\"\u003e\u003cspan\u003e 700 µm x 700 µm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e   Working distance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cmeta charset=\"UTF-8\"\u003e \u003cspan\u003e1.1 mm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e   Frame rate\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026gt; 45 fps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003e\u003cstrong\u003eFluorescence recording\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e   Excitation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e540 \/ 15 nm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e   Emission\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e609 \/ 57 nm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/li\u003e\n\u003cli id=\"tab4\"\u003eThe GCaMP + Red Opsins Surface Microscopy System is optimized for GFP-like fluorescence proteins imaging and Red Opsins (e.g. NpHR3.0, Chrimson, ...) activation. \u003cbr\u003e\u003cbr\u003eThe system includes: \u003cbr\u003e\u003cspan style=\"float: right; padding-right: 10px;\"\u003e \u003cimg width=\"400\" style=\"float: right;\" alt=\"\" src=\"https:\/\/doriclenses.com\/downloads\/Website\/OSMS-GCaMP-RedOpsin-2-20.jpg\"\u003e \u003c\/span\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/snap-in-fluorescence-microscope-bodies-model-s\" target=\"_blank\"\u003eSnap-in GCaMP\/NpHR Fluorescence Microscope Body, Model S\u003c\/a\u003e, the head mounted microscope\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/fluorescence-microscope-driver\" target=\"_blank\"\u003eFluorescence Microscope Driver\u003c\/a\u003e, to control the microscope\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/liser-led-fiber-light-source?\" target=\"_blank\"\u003e★LISER™ Light Source\u003c\/a\u003e with \u003ca href=\"\/products\/liser-bandpass-filters?\" target=\"_blank\"\u003e612\/69 nm bandpass filter\u003c\/a\u003e, for GCaMP excitation and Red Opsins activation\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/otpg\" target=\"_blank\"\u003eOptogenetics TTL Pulse Generators 4 Channels\u003c\/a\u003e, for imaging and optogenetic stimulation synchronization\u003c\/li\u003e\n\u003cli\u003eOptical fiber patch cords, to connect the light source to the microscope\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/fluorescence-microscope-holder?\" target=\"_blank\"\u003eFluorescence Microscope Holder\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/clamp-for-fluorescence-microscope-holder\" target=\"_blank\"\u003eClamp for Fluorescence Microscope Holder\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/doric-neuroscience-studio\" target=\"_blank\"\u003eDoric Neuroscience Studio\u003c\/a\u003e Software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003eAdd optional items:\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/assisted-1x1-pigtailed-fiber-optic-electric-rotary-joints-24-contacts?\" target=\"_blank\"\u003eAssisted 1x1 Pigtailed Fiber-optic \u0026amp; Electric Rotary Joint - 24 contacts\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/dummy-microscope?\" target=\"_blank\"\u003eSnap-in Microscope Dummy, Model S\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/neuro.doriclenses.com\/collections\/behavior-camera\/products\/behavior-camera\"\u003eBehavior Camera\u003c\/a\u003e to record animal behavior\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/neuro.doriclenses.com\/products\/computeur?_pos=1\u0026amp;_sid=200a6c079\u0026amp;_ss=r\u0026amp;productoption%5BWorkstation%3A%5D=High%20performance\"\u003eWorkstation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/neuro.doriclenses.com\/products\/danse\"\u003edanse™\u003c\/a\u003e analyzing software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003eComplete your system with:\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/snap-in-imaging-cannula-model-s\" target=\"_blank\"\u003eSnap-in Imaging Cannula, Model S\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/protrusion-adjustment-ring-set\" target=\"_blank\"\u003eProtrusion Adjustment Ring Set Model S\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003ctable class=\"table-data-sheet\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e   Field of View\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60%;\"\u003e\u003cspan\u003e 700 µm x 700 µm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e   Working distance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cmeta charset=\"UTF-8\"\u003e \u003cspan\u003e1.1 mm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e   Frame rate\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026gt; 45 fps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003e\u003cstrong\u003eFluorescence recording\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e   Excitation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e458 \/ 35 nm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e   Emission\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e525 \/ 40 nm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003e\u003cstrong\u003eOptogenetic stimulation\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e   Wavelength\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e612 \/ 69 nm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e   Activation intensity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 55 mW \/ mm2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/li\u003e\n\u003cli id=\"tab5\"\u003eThe Red Fluorescence + Blue Opsins Surface Microscopy System is optimized for RFP-like fluorescence proteins imaging and Blue Opsins (e.g. ChR2) activation. \u003cbr\u003e\u003cbr\u003eThe system includes: \u003cbr\u003e\u003cspan style=\"float: right; padding-right: 10px;\"\u003e \u003cimg width=\"400\" style=\"float: right;\" alt=\"\" src=\"https:\/\/doriclenses.com\/downloads\/Website\/OSMS-Red-fluo-ChR2-2-20.jpg\"\u003e \u003c\/span\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/snap-in-fluorescence-microscope-bodies-model-s\" target=\"_blank\"\u003eSnap-in RCaMP\/ChR2 Fluorescence Microscope Body, Model S\u003c\/a\u003e, the head mounted microscope\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/fluorescence-microscope-driver\" target=\"_blank\"\u003eFluorescence Microscope Driver\u003c\/a\u003e, to control the microscope\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/liser-led-fiber-light-source?\" target=\"_blank\"\u003e★LISER™ Light Source\u003c\/a\u003e with \u003ca href=\"\/products\/liser-bandpass-filters?\" target=\"_blank\"\u003e540\/15 nm bandpass filter\u003c\/a\u003e, for GCaMP excitation and Red Opsins activation\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/otpg\" target=\"_blank\"\u003eOptogenetics TTL Pulse Generators 4 Channels\u003c\/a\u003e, for imaging and optogenetic stimulation synchronization\u003c\/li\u003e\n\u003cli\u003eOptical fiber patch cords, to connect the light source to the microscope\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/fluorescence-microscope-holder?\" target=\"_blank\"\u003eFluorescence Microscope Holder\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/clamp-for-fluorescence-microscope-holder\" target=\"_blank\"\u003eClamp for Fluorescence Microscope Holder\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/doric-neuroscience-studio\" target=\"_blank\"\u003eDoric Neuroscience Studio\u003c\/a\u003e Software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003eAdd optional items:\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/assisted-1x1-pigtailed-fiber-optic-electric-rotary-joints-24-contacts?\" target=\"_blank\"\u003eAssisted 1x1 Pigtailed Fiber-optic \u0026amp; Electric Rotary Joint - 24 contacts\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/dummy-microscope?\" target=\"_blank\"\u003eSnap-in Microscope Dummy, Model S\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cimg\u003e\u003cimg\u003e\u003cimg\u003e\u003cimg\u003e\u003ca href=\"https:\/\/neuro.doriclenses.com\/collections\/behavior-camera\/products\/behavior-camera\"\u003eBehavior Camera\u003c\/a\u003e \u003ca href=\"https:\/\/neuro.doriclenses.com\/collections\/behavior-camera\/products\/camloop\"\u003e\u003c\/a\u003e to record animal behavior\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/neuro.doriclenses.com\/products\/computeur?_pos=1\u0026amp;_sid=200a6c079\u0026amp;_ss=r\u0026amp;productoption%5BWorkstation%3A%5D=High%20performance\"\u003eWorkstation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/neuro.doriclenses.com\/products\/danse\"\u003edanse™\u003c\/a\u003e analyzing software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003eComplete your system with:\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/snap-in-imaging-cannula-model-s\" target=\"_blank\"\u003eSnap-in Imaging Cannula, Model S\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/protrusion-adjustment-ring-set\" target=\"_blank\"\u003eProtrusion Adjustment Ring Set Model S\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003ctable class=\"table-data-sheet\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e   Field of View\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60%;\"\u003e\u003cspan\u003e 700 µm x 700 µm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e   Working distance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cmeta charset=\"UTF-8\"\u003e \u003cspan\u003e1.1 mm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e   Frame rate\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026gt; 45 fps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003e\u003cstrong\u003eFluorescence recording\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e   Excitation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e540 \/ 15 nm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e   Emission\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e609 \/ 57 nm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003e\u003cstrong\u003eOptogenetic stimulation\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e   Wavelength\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e465 \/ 20 nm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/li\u003e\n\u003cli id=\"tab6\"\u003e\n\u003ctable style=\"width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr data-darkreader-inline-bgcolor=\"\" style=\"background-color: #eeeeee;\"\u003e\n\u003ctd data-darkreader-inline-border-left=\"\" data-darkreader-inline-border-bottom=\"\" data-darkreader-inline-border-right=\"\" data-darkreader-inline-border-top=\"\" style=\"border: 0px; width: 100%; display: grid; grid-template-columns: 80% 10% 10%; padding: 5px 5px 5px 5px 0px 5px;\"\u003e\n\u003cspan style=\"padding: 0px 0px 0px 10px; margin: 0px 0px 1px 0px; white-space: nowrap;\"\u003e\u003cstrong\u003eUser Manual\u003c\/strong\u003e\u003c\/span\u003e\u003cspan style=\"padding: 0px 0px 0px 10px; margin: 0px 0px 1px 0px; white-space: nowrap; text-align: center;\"\u003e\u003cstrong\u003eFr\u003c\/strong\u003e\u003c\/span\u003e\u003cspan style=\"padding: 0px 0px 0px 10px; margin: 0px 0px 1px 0px; white-space: nowrap; text-align: center;\"\u003e\u003cstrong\u003eEn\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-darkreader-inline-border-left=\"\" data-darkreader-inline-border-bottom=\"\" data-darkreader-inline-border-right=\"\" data-darkreader-inline-border-top=\"\" style=\"border: 0px; width: 100%; display: grid; grid-template-columns: 80% 10% 10%; padding: 5px 5px 5px 5px 0px 5px;\"\u003e\n\u003cp data-darkreader-inline-border-left=\"\" data-darkreader-inline-border-bottom=\"\" data-darkreader-inline-border-right=\"\" data-darkreader-inline-border-top=\"\" style=\"margin: 0 0 0 40px; border: none; padding: 0px;\"\u003eSingle-color Miniature Fluorescence Microscopy System\u003c\/p\u003e\n\u003ca title=\"Manuel utilisateur pour le Système de microscopie miniature à fluorescence une couleur\" href=\"https:\/\/doriclenses.com\/downloads\/UserManual\/UserManual_SFMB_OSFM_FR_V3.3.3.pdf\" target=\"_blank\"\u003e\u003ci data-darkreader-inline-color=\"\" style=\"margin: 0 0 0 47px; color: #3687ff;\" class=\"fas fa-file-pdf fa-2x\"\u003e\u003c\/i\u003e\u003c\/a\u003e \u003ca title=\"Single-color Miniature Fluorescence Microscopy System User Manual\" href=\"https:\/\/doriclenses.com\/downloads\/UserManual\/UserManual_SFMB_OSFM_V3.3.3.pdf\" target=\"_blank\"\u003e\u003ci data-darkreader-inline-color=\"\" style=\"margin: 0 0 0 47px; color: firebrick;\" class=\"fas fa-file-pdf fa-2x\"\u003e\u003c\/i\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-darkreader-inline-bgcolor=\"\" style=\"background-color: #eeeeee;\"\u003e\n\u003ctd data-darkreader-inline-border-left=\"\" data-darkreader-inline-border-bottom=\"\" data-darkreader-inline-border-right=\"\" data-darkreader-inline-border-top=\"\" style=\"border: 0px; width: 100%; display: grid; grid-template-columns: 80% 10% 10%; padding: 5px 5px 5px 5px 0px 5px;\"\u003e\n\u003cspan style=\"padding: 0px 0px 0px 10px; margin: 0px 0px 1px 0px; white-space: nowrap;\"\u003e\u003cstrong\u003eApplication Note\u003c\/strong\u003e\u003c\/span\u003e\u003cspan style=\"padding: 0px 0px 0px 10px; margin: 0px 0px 1px 0px; white-space: nowrap; text-align: center;\"\u003e\u003cstrong\u003eFr\u003c\/strong\u003e\u003c\/span\u003e\u003cspan style=\"padding: 0px 0px 0px 10px; margin: 0px 0px 1px 0px; white-space: nowrap; text-align: center;\"\u003e\u003cstrong\u003eEn\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-darkreader-inline-border-left=\"\" data-darkreader-inline-border-bottom=\"\" data-darkreader-inline-border-right=\"\" data-darkreader-inline-border-top=\"\" style=\"border: 0px; width: 100%; display: grid; grid-template-columns: 80% 10% 10%; padding: 5px 5px 5px 5px 0px 5px;\"\u003e\n\u003cp data-darkreader-inline-border-left=\"\" data-darkreader-inline-border-bottom=\"\" data-darkreader-inline-border-right=\"\" data-darkreader-inline-border-top=\"\" style=\"margin: 0 0 0 40px; border: none; padding: 0px;\"\u003eImaging Cannula Implantation \u0026amp; Single-colorMicroscope Installation\u003c\/p\u003e\n\u003ca title=\"Note d’Application pour Implantation de la Canule d'Imagerie et Installation du Microscope Une-Couleur\" href=\"http:\/\/www.doriclenses.com\/downloads\/ApplicationNotes\/ApplicationNote_SFMB_OSFM_FR_V1.4.1.pdf\" target=\"_blank\"\u003e\u003ci data-darkreader-inline-color=\"\" style=\"margin: 0 0 0 47px; color: #3687ff;\" class=\"fas fa-file-pdf fa-2x\"\u003e\u003c\/i\u003e\u003c\/a\u003e \u003ca title=\"Imaging Cannula Implantation \u0026amp; Single-colorMicroscope Installation Application Note\" href=\"http:\/\/www.doriclenses.com\/downloads\/ApplicationNotes\/ApplicationNote_SFMB_OSFM_V1.4.1.pdf\" target=\"_blank\"\u003e\u003ci data-darkreader-inline-color=\"\" style=\"margin: 0 0 0 47px; color: firebrick;\" class=\"fas fa-file-pdf fa-2x\"\u003e\u003c\/i\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-darkreader-inline-border-left=\"\" data-darkreader-inline-border-bottom=\"\" data-darkreader-inline-border-right=\"\" data-darkreader-inline-border-top=\"\" style=\"border: 0px; width: 100%; display: grid; grid-template-columns: 80% 10% 10%; padding: 5px 5px 5px 5px 0px 5px;\"\u003e\n\u003cp data-darkreader-inline-border-left=\"\" data-darkreader-inline-border-bottom=\"\" data-darkreader-inline-border-right=\"\" data-darkreader-inline-border-top=\"\" style=\"margin: 0 0 0 40px; border: none; padding: 0px;\"\u003eGCaMP configuration filter set\u003c\/p\u003e\n\u003ca href=\"http:\/\/www.doriclenses.com\/downloads\/ApplicationNotes\/ApplicationNote_SFM_filter_Traces_GCaMP_FR_V1.1.pdf\" title=\"Note d’Application pour l'Ensemble de filtres pour la configuration GCaMP\" target=\"_blank\"\u003e\u003ci data-darkreader-inline-color=\"\" class=\"fas fa-file-pdf fa-2x\" style=\"margin: 0 0 0 47px; color: #3687ff;\"\u003e\u003c\/i\u003e\u003c\/a\u003e \u003ca href=\"http:\/\/www.doriclenses.com\/downloads\/ApplicationNotes\/ApplicationNote_SFM_filter_Traces_GCaMP_V1.1.pdf\" title=\"GCaMP configuration filter set Application Note\" target=\"_blank\"\u003e\u003ci data-darkreader-inline-color=\"\" class=\"fas fa-file-pdf fa-2x\" style=\"margin: 0 0 0 47px; color: firebrick;\"\u003e\u003c\/i\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-darkreader-inline-border-left=\"\" data-darkreader-inline-border-bottom=\"\" data-darkreader-inline-border-right=\"\" data-darkreader-inline-border-top=\"\" style=\"border: 0px; width: 100%; display: grid; grid-template-columns: 80% 10% 10%; padding: 5px 5px 5px 5px 0px 5px;\"\u003e\n\u003cp data-darkreader-inline-border-left=\"\" data-darkreader-inline-border-bottom=\"\" data-darkreader-inline-border-right=\"\" data-darkreader-inline-border-top=\"\" style=\"margin: 0 0 0 40px; border: none; padding: 0px;\"\u003eRCaMP configuration filter set\u003c\/p\u003e\n\u003ca href=\"http:\/\/www.doriclenses.com\/downloads\/ApplicationNotes\/ApplicationNote_SFM_filter_Traces_RCaMP_FR_V1.2.pdf\" title=\"Note d’Application pour l'Ensemble de filtres pour la configuration RCaMP\" target=\"_blank\"\u003e\u003ci data-darkreader-inline-color=\"\" class=\"fas fa-file-pdf fa-2x\" style=\"margin: 0 0 0 47px; color: #3687ff;\"\u003e\u003c\/i\u003e\u003c\/a\u003e \u003ca href=\"http:\/\/www.doriclenses.com\/downloads\/ApplicationNotes\/ApplicationNote_SFM_filter_Traces_RCaMP_V1.2.pdf\" title=\"Ensemble de filtres pour la configuration RCaMP Application Note\" target=\"_blank\"\u003e\u003ci data-darkreader-inline-color=\"\" class=\"fas fa-file-pdf fa-2x\" style=\"margin: 0 0 0 47px; color: firebrick;\"\u003e\u003c\/i\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-darkreader-inline-border-left=\"\" data-darkreader-inline-border-bottom=\"\" data-darkreader-inline-border-right=\"\" data-darkreader-inline-border-top=\"\" style=\"border: 0px; width: 100%; display: grid; grid-template-columns: 80% 10% 10%; padding: 5px 5px 5px 5px 0px 5px;\"\u003e\n\u003cp data-darkreader-inline-border-left=\"\" data-darkreader-inline-border-bottom=\"\" data-darkreader-inline-border-right=\"\" data-darkreader-inline-border-top=\"\" style=\"margin: 0 0 0 40px; border: none; padding: 0px;\"\u003eGCaMP\/NpHR configuration filter set\u003c\/p\u003e\n\u003ca href=\"http:\/\/www.doriclenses.com\/downloads\/ApplicationNotes\/ApplicationNote_OSFM_filter_Traces_GCaMP_NpHR3_FR_V1.4.pdf\" title=\"Note d’Application pour le Jeu de Filtres pour la Configuration GCaMP2\/NpHR pour Microscope à Fluorescence\" target=\"_blank\"\u003e\u003ci data-darkreader-inline-color=\"\" class=\"fas fa-file-pdf fa-2x\" style=\"margin: 0 0 0 47px; color: #3687ff;\"\u003e\u003c\/i\u003e\u003c\/a\u003e \u003ca href=\"http:\/\/www.doriclenses.com\/downloads\/ApplicationNotes\/ApplicationNote_OSFM_filter_Traces_GCaMP_NpHR3_V1.4.pdf\" title=\"Optogeneticaly Synchronized Fluorescence Microscope GCaMP\/NpHR configuration filter set Application Note\" target=\"_blank\"\u003e\u003ci data-darkreader-inline-color=\"\" class=\"fas fa-file-pdf fa-2x\" style=\"margin: 0 0 0 47px; color: firebrick;\"\u003e\u003c\/i\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-darkreader-inline-border-left=\"\" data-darkreader-inline-border-bottom=\"\" data-darkreader-inline-border-right=\"\" data-darkreader-inline-border-top=\"\" style=\"border: 0px; width: 100%; display: grid; grid-template-columns: 80% 10% 10%; padding: 5px 5px 5px 5px 0px 5px;\"\u003e\n\u003cp data-darkreader-inline-border-left=\"\" data-darkreader-inline-border-bottom=\"\" data-darkreader-inline-border-right=\"\" data-darkreader-inline-border-top=\"\" style=\"margin: 0 0 0 40px; border: none; padding: 0px;\"\u003eRCaMP\/ChR2 configuration filter set\u003c\/p\u003e\n\u003ca href=\"http:\/\/www.doriclenses.com\/downloads\/ApplicationNotes\/ApplicationNote_OSFM_filter_Traces_RCaMP-ChR2_FR_V1.2.pdf\" title=\"Note d’Application pour le Jeu de Filtres pour la Configuration RCaMP2\/ChR2 pour Microscope à Fluorescence\" target=\"_blank\"\u003e\u003ci data-darkreader-inline-color=\"\" class=\"fas fa-file-pdf fa-2x\" style=\"margin: 0 0 0 47px; color: #3687ff;\"\u003e\u003c\/i\u003e\u003c\/a\u003e \u003ca href=\"http:\/\/www.doriclenses.com\/downloads\/ApplicationNotes\/ApplicationNote_OSFM_filter_Traces_RCaMP-ChR2_V1.2.pdf\" title=\"RCaMP\/ChR2 configuration filter set Application Note\" target=\"_blank\"\u003e\u003ci data-darkreader-inline-color=\"\" class=\"fas fa-file-pdf fa-2x\" style=\"margin: 0 0 0 47px; color: firebrick;\"\u003e\u003c\/i\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Doric Lenses Inc.","offers":[{"title":"Default Title","offer_id":34463398658180,"sku":"","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0306\/2680\/7940\/products\/SFMS-GCaMP.jpg?v=1647954132","url":"https:\/\/archive.neuro.doriclenses.com\/products\/snap-in-surface-fluorescence-microscopy-systems","provider":"Doric Lenses - Archive","version":"1.0","type":"link"}